Alarm I/O Setup - Jaycar Electronics DS-8704HI-S User Manual

Ds-8700 series net dvr
Table of Contents

Advertisement

5.12 Alarm I/O Setup

For 4-channel DVR, there are 4 external alarm input and 2 relay output. For 8 or
16-channel DVR, there are 16 external alarm input and 4 relay output.
Note: For 8704HI-S is 4 external alarm input and 2 relay output.
In "Alarms" menu, you can setup each external alarm input.
In main menu, move "Active Frame" to "Alarms" icon and press [ENTER] key to enter
into alarms menu:
External alarm input setup:
Step 1: Select one alarm input Use [↑] [↓] keys to select one alarm input. You can
change the Alarm in Name in box "Alarm In Name"
Step 2: Alarm type
This is sensor type. You can select "Normal Open" or "Normal Close" according to the
sensor type.
Step 3: Enter into "Alarm in Handling" sub menu
In the "Alarms" menu, there are two options for "Alarm Handling" item. One is "Ignore",
and the other is "Handle". If you select "Handle" option, you can active "Policy" and "PTZ
Linkage" buttons on right side. Move "Active Frame" to "Policy" button and press [ENTER]
key, you will enter into "Alarm in Handling" sub menu:
88

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds-8708hi-sDs-8716hi-s

Table of Contents