6.1.6
Siemens AB
Security Products
closed again or a severed X-BUS connection re-established. The SPC system
does NOT provide the Restore option without detection of the restored fault.
Users may be restricted from using the Restore feature if an Engineer chooses not
to select Restore within the user rights menu for select users. Users who cannot
restore an alert receive fault messages on the keypad until the zone or fault
condition is either inhibited or isolated.
An alert condition only displays on the keypad when the system is UNSET. If the
system is SET when an alert condition occurs, the keypad gives no indication of
that alert condition until such time as the system is UNSET.
To restore an alert condition triggered by a zone opening:
1. Locate the open zone (displays on the keypad).
2. Restore the alarm sensor to its normal state by closing the door or window.
3. Enter a valid user code and select the RESTORE option (right soft key).
 The zone that caused the alert displays on the top line.
4. Press the right menu key to restore the alert.
 The message ALL ALERTS RESTORED displays.
 The flashing Alert LED turns off.
For system or communications type alert conditions (mains failure or X-BUS
disconnect):
1. Locate the source of the alert condition.
2. Check that all wires and cables are properly connected.
For a tamper alert:
1. Ensure the lids on all enclosures and devices are correctly closed.
If the physical fault cannot be restored to its normal operating state, please
contact the installation engineer.
2. The alarm system still operates by either inhibiting or isolating the fault
condition.

CODED RESTORE

The feature provides the user with the ability to restore alert conditions that would
normally only be available to the installation engineer. To provide the user with this
ability, it is necessary to protect this feature with a code.
To perform a coded restore on the system:
 The security grade of the system must be set to Grade 3 or Unrestricted.
 Ensure that the zone or fault that caused the alert condition has been
physically restored to its normal operating state.
 Contact the installer before entering user programming and selecting the coded
restore feature. The contact details of the installer should be available from the
drop down label beneath the keypad.
1. Press SELECT on the Coded Restore option.
User programming via the keypad
Setting and unsetting the system
6
17
A6V10209178
26.09.2011