Specifications - Noritz N-132M Owner's Manual And Installation Manual

Noritz n-132m gas water heater - owner's guide and installation manual
Table of Contents

Advertisement

Specifications

Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
26
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
45°F Rise
Specification
N-132M
Indoor/ Outdoor, Wall Hanging
Power Vented
Direct Ignition
15-150 PSI
0.7 GPM
29.5"(Height) x 18.9"(Width) x 11.8"(Depth)
105 lbs.
0.6 Gallon
1"
1"
3/4"
120 VAC (60Hz)
NG:137W, LP:142W, Freeze Prevention 371W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Back Pressure Switch, Lightning Protection Device
(ZNR), Electric Leakage Prevention Device (GFCI),
Overheat Prevention Device, Freezing Prevention
Device, Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Maximum Performance
380,000 btuh
380,000 btuh
13.2 Gal./min.
0.7 -13.2 Gal./min.
100-150°F (In 5°F intervals),
160, 170, 180°F (In 10°F intervals) (14 Options)
120,130,140,180°F(Original is 120°F)
Minimum Performance
22,500 btuh
22,500 btuh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents