Specifications - Noritz NR98-DVC-CA Owner's Manual

Tankless gas water heater
Hide thumbs Also See for NR98-DVC-CA:
Table of Contents

Advertisement

Specifications

Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
25°C (45°F) Rise
pressure, water supply, piping conditions, and water temperature.
Indoor Wall Mounted
2 L/min. (0.5 GPM)
600mm (23.6") x 350mm (13.8") x 270mm (10.2")
0.95L (0.2 Gallon)
120 VAC (60Hz)
NG : 108W LP : 96W
Zincified Steel Plate/Polyester Coating
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Electric Leakage Prevention Device
(GFCI), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Anchoring Screws
Maximum Performance
199,900 btuh
199,900 btuh
28.2 L/min. (7.5 Gal./min.)
2-37 L/min. (0.5-9.8 Gal./min.)
37-48°C (99-118°F) (In 1°C (5°F) intervals),
50-80°C (122-176°F) (In 5°C (10°F) intervals),
83°C (181°F) (20 Options)
50, 55, 60, 83°C (122,131,140,181°F)
(Original is 50°C (122°F))
Specification
NR98-DVC-CA
Power Vented
Direct Ignition
15-150 psi
55 lbs.
3/4"
3/4"
3/4"
Freeze Prevention 161W
Stainless Steel
Minimum Performance
11,000 btuh
11,000 btuh
27

Advertisement

Table of Contents
loading

Table of Contents