Specifications - Noritz NC1991-OD-LP Owner's Manual

Tankless gas water heater
Table of Contents

Advertisement

Specifications-1

Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
NG
LP
45°F (25°C) Rise
°F Mode:
°C Mode:
Specification
NC1991-OD
Outdoor Wall Mounted
Power Vented
Direct Ignition
15-150 psi
0.5 GPM (2 L/min.)
23.6" (600mm) x 13.8" (350mm) x 9.4" (240mm)
0.2 Gallon (1.0L)
120 VAC (60Hz)
NG : 65W LP : 67W Freeze Prevention 161W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Maximum Performance
199,900 btuh
199,900 btuh
7.5 GPM (28.2 L/min.)
0.5-9.8 GPM (2-37 L/min.)
100-150°F (In 5°F intervals),
160, 170, 185°F (14 Options)
37-48°C (In 1°C intervals),
50-85°C (In 5°C intervals) (20 Options)
120°F (50°C),135°F (57°C),140°F (60°C),185°F (85°C)
(Original is 120°F (50°C))
54 lbs.
3/4"
3/4"
3/4"
Minimum Performance
16,000 btuh
16,000 btuh
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nc1991-dvcNc1991-odNc1991-dvc-ngNc1991-dvc-lp