DIP switch settings

For serial interface models
Table 6-2 DIP switch settings for serial interface models
Switch number
Function
1
Power switch function
2
Setting for serial communication
conditions
3
Handshake
4
Bit length
5
Parity check
6
Parity selection
7
Baud rate selection
8
Table 6-3 Baud rate selection
Transmission speed
[ bps ]
2400
4800
9600
19200
bps: bits per second
Note: About the setting for serial communication conditions.
When DIP switch 2 is "ON", you can set for serial communication conditions by the DIP switch.
In case of OFF, it doesn't enables to set by the DIP switch, but by the memory switch. Then you
need to run the Memory Switch Setting Mode.
For non-serial interface models
Table 6-4 DIP switch settings for non-serial interface models
Switch number
Function
1
Power switch function
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6-10 Installation
ON
Disabled
To be specified with DIP
switches.
XON/XOFF
7 bits
Yes
Even
See the next table.
Switch number
7
ON
OFF
ON
OFF
ON
Disabled
-
-
-
-
OFF
Enabled
To be specified with NV
memory.
DTR/DSR
8 bits
No
Odd
8
ON
ON
OFF
OFF
OFF
Enabled
Fixed to off
Fixed to off
Fixed to off
Fixed to off