6.2.1 Printhead-Platen Distance Adjustment
1.
Open the top cover.
2.
Remove the paper and the ribbon.
3.
Set the paper thickness adjustment lever to position 1.
4.
Slacken off the printhead retaining screws (A).
5.
Using feeler gauges or the gauge supplied with the new printhead FRU, set the
printhead-platen gap to 0.30 − 0.35 mm.
6.
Tighten the printhead retaining screws (A).
Figure 6.2 Printhead-Platen distance adjustment
LA 310 - Service Manual
6-5