Emerson BRADSHAW CF890BS00 Owner's Manual page 18

52” ceiling fan
Table of Contents

Advertisement

7. Wall Control Procedures
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY & HIGH SPEED
CONDITIONING OF FAN CONTROL
IMPORTANT: Ceiling fan blades MUST be installed
before high speed conditioning can begin.
7.24
Within 1 minute of restoring electricity to the ceiling fan,
push and hold the fan OFF button (
seconds to set the code in the receiver. The ceiling fan
lights (if installed) will blink to indicate the transmitted
has been paired with the receiver.
IMPORTANT: Immediately after successful pairing,
the ceiling fan will automatically begin high speed
conditioning of the motor. During conditioning, the
electronic motor control software is calculating
speeds for the 2nd through 5th speed settings
based on the blades that were installed on the fan.
7.25
The fan will run for approximately 2 minutes in the
upward direction then reverse direction to down flow
and run an additional 2 minutes. When conditioning is
complete, the fan will come to complete stop.
USING YOUR CEILING FAN
Your wall control has full control of your fan and light.
NOTE: Prior to operation of the fan and light from
the wall control, set the fan speed to HIGH ( .... ) and
turn the light ON (
).
7.29
To set the desired fan speed, press one of the four
buttons ( . , .. , ... , .... ) to operate your fan on from low to
high speeds (Figure 26).
7.30
To turn the light on and off, press and release the
LIGHT (
) button. To set the light intensity, press and
hold the LIGHT (
) button. The light will turn on at the
light intensity previously selected.
7.31
Your fan is now wired to be turned on and off from the
fan switch.
IMPORTANT: Do not interrupt the conditioning until
the fan comes to a complete stop in approximately 5
minutes. All functions of the control will be rejected
during conditioning.
7.26
High speed conditioning is now complete.
7.27
) for 3 to 5
If programming is unsuccessful, retry the above
instructions after cycling the wall control ON/OFF switch
to restart the 1 minute programming time period.
7.28
If still unsuccessful, shut off the electricity at the fuse
box or breaker panel and change the wall control
frequency (page 14). After changing the frequency
settings, repeat instruction #1 of this section within one
minute of restoring the electricity.
Fan installation must be completed, including the
installation of the fan blades, before testing the remote
control.
POWER
INDICATOR
LIGHT
LIGHT BUTTON
FAN BUTTON
Figure 26
18
(continued)
WARNING
!
....
OFF
ON
ETL Model No.: CF890
HIGH TO LOW
BUTTONS
ON/OFF SWITCH
O = OFF / — = ON