7. Wall Control Procedures
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire Is
required (See Figure 25).
WARNING
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
7.19
Screw wall control into wall box using the supplied
screws. Leave wall control in "OFF" mode until fan
installation is completed.
7.20
The wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that best
suits your needs and snap the cover onto the wall
control (Figure 25).
7.21
Next, install the other wall control into the wall box
containing the load wire. Connect the black wire of the
wall control to the traveler wire(s) already connected to
the black wire (in the other wall box). Secure with wire
connectors supplied.
7.22
Connect one black wire of the wall control to the "load"
(black) wire and secure with wire connector supplied.
7.23
Connect one black wire of the wall control to both
remaining traveler wires in the wall box and secure with
wire connector supplied.
(continued)
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
WALL CONTROL
HOT
BLK
TRAVELER WIRES
3-WAY WIRING DIAGRAM: RETROFIT
BLK
HOT
BLK
....
HI
LIGHT
MED
LOW
FAN OFF
EMERSON
®
OFF
ON
OFF
ON
FAN/LIGHT
WALL
CONTROL
Figure 25
Please contact 1-800-654-3545 for further assistance
17
EXISTING
LOAD
BLK
BLK
....
HI
LIGHT
MED
LOW
FAN OFF
EMERSON
®
OFF
ON
OFF
ON
FAN/LIGHT
TRAVELER
WALL
LOAD
WIRES
CONTROL
emersonfans.com