4.15 User Buttons SW1, SW2, SW3, SW4, SW5 (JP: 12, 14, 16, 20, 23)

Five user push buttons (SW1-SW5) can be connected to the microcontroller.
JP12, 14, 16, 20, 23 Each push button can be connected separately.
Jumper
JP12
(SW1)
JP14
(SW2)
JP16
(SW3)
JP20
(SW4)
JP23
(SW5)
Rule 8: By default all push-buttons are connected to the microcontroller.
© Fujitsu Semiconductor Europe GmbH
SK-96620_350-64PMC(1) User Guide
Chapter 4 Jumpers and Switches
Setting
Description
Pin 31 (P05_6/INT15) of the MCU is connected to "SW1"
Closed
Open
No connection to the microcontroller
Pin 30 (P02_4/INT14) of the MCU is connected to "SW2"
Closed
Open
No connection to the microcontroller
Pin 32 (P02_5/TIN1) of the MCU is connected to "SW3"
Closed
Open
No connection to the microcontroller
Pin 44 (P01_0/IN0) of the MCU is connected to "SW4"
Closed
Open
No connection to the microcontroller
Pin 51 (P07_0/IN1) of the MCU is connected to "SW5"
Closed
Open
No connection to the microcontroller
Table 4-16: User Push Buttons