Memory Specifications; Optical Port Specifications; Serial Port Specifications - HP Surestore fc 1Gb/2Gb switch 16B Installation And Reference Manual

Hp switch user manual
Hide thumbs Also See for Surestore fc 1Gb/2Gb switch 16B:
Table of Contents

Advertisement

Table A-4
Port to port latency
Data transmission range
Immunity

Memory Specifications

The FC 16B has the following memory:
Main Memory: 16 MB per switch
Flash Memory: 16MB of 16-bit wide memory, stored in 2 banks of 8M-bytes each
Boot Flash: 512K bytes of 8-bit for system boot
The centralized memory maximizes the overall switch throughput by guaranteeing full transmit and
receive bandwidth to all Fibre Channel ports at all times.

Optical Port Specifications

The optical ports in the FC 16B are compatible with SWL (short wave-length) and LWL (long
wave-length) SFPs (small form factor pluggable media) and SFP-compatible cables. The strength
of the signal is determined by the type of SFP in use.
The ports meet all required safety standards. For more information about these standards, see
Regulatory Compliance on page A-7.
The ports are capable of operating at 2.125 Gbps or 1.0625 Gbps. Each port has a SerDes
(serializer/de-serializer) which accepts 10-bit wide parallel data and serializes it into a high-speed
serial stream. The parallel data is expected to be "8B/10B" encoded data or equivalent.

Serial Port Specifications

The serial port has an RS-232 connector, and is located in the SFP media side of the switch.
Note:
The serial port can be used to connect to a computer workstation to configure the switch IP address
without connecting to the fabric. The serial port's parameters are 9600 baud, 8 data bits, no parity, 1
stop bit, and no flow control.
HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide
General Specifications (Continued)
Less than 2 microseconds with no contention (destination port
is free)
Up to 500 m (1,625 ft.) for short-wavelength optical link
Up to 10 km (32,820 ft.) for long-wavelength optical link
IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge
IEC 61000-4-3 Severity Level 3 for Radiated Fields
IEC 61000-4-4 Severity Level 3 for Fast Transients
IEC 61000-4-5 Severity Level 3 for Surge Voltage
IEC 61000-4-6 Conducted Emissions
IEC 61000-4-11 Voltage Variations
For dust and ESD (electrostatic discharge) protection, a cover is provided for the serial port
and should be kept on the port whenever the serial port is not in use.
A
Product Specifications
A-5

Advertisement

Table of Contents
loading

Table of Contents