Table 3-2 describes the LEDs on the power supply side of the switch.
Table 3-2
Location
of LED
On each
power
supply
Center of
power
supply
side

Interpreting POST Results

Each time the switch is powered on or reset, the switch automatically performs POST, a one minute
system check during which the port status LEDs flash different colors.
To determine whether POST completed without errors, verify that all LEDs return to a normal state
after POST is complete. If one or more LEDs do not return to a normal state, and this is not due to
the switch being set to beacon, see Interpreting LED Activity on page 3-1 (for more information
about beaconing, refer to the Fabric OS Procedures Guide).
Note:
Any errors detected during POST are written to the system log, accessible through the errShow
command. For more information about error messages, refer to the Fabric OS Reference.
HP Surestore FC 1Gb/2Gb Switch 16B Installation and Reference Guide
Operating the HP Surestore FC 1Gb/2Gb Switch 16B
Power Supply Side LED Patterns During Normal Operation
Purpose
Color of LED
of LED
Indicates
No light
status of
related
power
supply
Steady green
Indicates
No light
switch
status
Steady green
Steady yellow
Slow-flashing
yellow
If the switch prompt does not display when POST completes, POST was not successfully
completed and the switch should be returned to your HP account representative for repair.
Status of Hardware
Power supply is not
providing power.
Power supply is providing
power.
Either the switch is off, or
boot is not complete, or
boot has failed.
Switch is on and boot has
successfully completed.
Diagnostic command is in
progress, or one or more
ports are faulty.
Diagnostic failure on one or
more ports.
3
Recommended
Action
Verify power supply is
on and power cable is
connected to a valid
power source.
No action required.
Verify that the switch
is on and boot has had
time to complete. If
there is still no light,
contact your HP
account representative.
No action required.
If no diagnostic tests
are running, check the
Port Status LEDs for
fault indicators.
Errors may be listed in
the error log. Refer to
the Fabric OS
Procedures Guide for
more information.
3-5