11. Address Switches

Address switches
The Type 2060 can be controlled via RS 485 commands
or 'up the co-ax'.
With RS 485 control each dome has to be individually
addressed using the Blue and Yellow rotary address
switches following the address chart on the previous page.
For 'up the co-ax' control, using the built in protocol converter,
the same address switches are used to select the protocol
format for the controller being used e.g.
BAX AC PANEL.................Blue.F Yellow.C = 252
For: Baxall a.c. controllers
DEN PANEL.......................Blue.F Yellow.D = 253
For: Dedicated Micros, BBV & DM Sprite controllers
BAX DC PANEL................Blue.F Yellow.E = 254
For: Baxall d.c. controllers
For 'up the co-ax' control using external protocol converters like
the drx 100 or DAX-DEN the address switches should be set to
Blue.0 Yellow.1 = 1.
To access the address switches remove the outer hemisphere
and inner shroud as shown in A & B. Picture C shows the
location. This operation should be carried out in an office type
environment to avoid ingress of moist air.