Motorola Canopy T1 User Manual page 38

Hide thumbs Also See for Canopy T1:
Table of Contents

Advertisement

Canopy  T1/E1 Multiplexer 
 
 
 
Action
Set T1 line code
Set timing mode
Set master clock
reference line
 
Issue 1
 
 
 
 
 
NOTE: If the line code does not match the incoming T1 settings, then Bipolar
Violations (BPVs) will occur. The default code is B8ZS.
Enter set line [1/2/3/4] code [B8ZS/AMI]
where
[1/2/3/4] represents T1 ports 1 through 4.
[B8ZS/AMI] represents the line coding scheme.
RESULT: The system responds
Line [1/2/3/4] code [B8ZS/AMI]
NOTE: Timing mode applies to all four T1 lines. Loopback mode loops the
T1/E1 Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock
from the incoming T1/E1 over Ethernet bit stream (recovers the clock from
the far end T1/E1). The default timing mode is Recovered.
Enter set clock source [loopback/recovered]
where
[loopback/recovered] represents the clock timing mode.
RESULT: The system responds
Clock source is [loopback/recovered]
NOTE: This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.
Enter set master clock reference line [1/2/3/4]
where
[1/2/3/4] represents T1/E1 ports 1 through 4.
RESULT: The system responds
Clk ref line; [1,2,3,4]
 
 
 
     
 
    T1/E1 Multiplexer Release 3.1 
Steps
 
 
          June 2004 
 38 of 69 
Page

Advertisement

Table of Contents
loading

This manual is also suitable for:

Canopy e1Canopy t1/e1

Table of Contents