Measurements From Diagnostics; License Key Upgrades; Figure 25: T1/E1 Port Upgrade Window; Table 13: Comparison Of Diagnostic Measurements - Motorola Canopy T1 User Manual

Hide thumbs Also See for Canopy T1:
Table of Contents

Advertisement

Canopy  T1/E1 Multiplexer 
 
 
 
3.5
MEASUREMENTS FROM DIAGNOSTICS 
A unit-based comparison of diagnostic measurements is provided in
Measurement
Description
Bit errors
Logic errors in
the bit stream
BPVs
Pulses of the
same consecutive
polarity
Frame errors
Incorrect values
in the framing
bit position
CRC errors
Bit errors in a
block of data
3.6
LICENSE KEY UPGRADES 
As previously described, you can transform any single-port enabled Canopy T1/E1
Multiplexer into a 2-port, 3-port, or 4-port multiplexer through the purchase and
installation of license keys from your Canopy distributor.

Procedure 29: Installing a license key to enable an additional port

To install a license key on a Canopy T1/E1 Multiplexer, perform the following steps.
1. From the main menu of the EMS, select Config→T1/E1 Port Upgrade.
RESULT: The Canopy T1/E1 Port Upgrade window opens, as shown in
Figure
 
Issue 1
 
 
 
 
 

Table 13: Comparison of diagnostic measurements

Availability
Only out of
service
In service
or out of
service
In service
or out of
service
In service
or out of
service
25.

Figure 25: T1/E1 Port Upgrade window

 
 
 
     
 
    T1/E1 Multiplexer Release 3.1 
Advantage
Best unit for
Requires that all traffic
point-to-point
be test traffic (known
performance
data pattern)
Good for circuit
Meaningful for only
or repeater
metallic media, because
problems
some equipment corrects
BPVs
Approximates
Evaluates only overhead
bit error rate on
bits
in-service basis
98.4% bit error
Available with only ESF
rate accuracy
framing
 
 
          June 2004 
Table
13.
Disadvantage
 56 of 69 
Page

Advertisement

Table of Contents
loading

This manual is also suitable for:

Canopy e1Canopy t1/e1

Table of Contents