7.2.4
EXPOSURE
7.2.5
SHUTTER
16
Siemens Building Technologies
Fire Safety & Security Products
D/N MODE
AUTO
D/N LEVEL
HIGH
D/N DELAY
15 sec
EXPOSURE
<ALC>
SHUTTER
1/50
GAIN
NORMAL
SYNC
LL:000
BLC
OFF
NEXT EXIT CANCEL DEFAULT
Fig. 4
EXPOSURE
This function sets ALC for Auto IRIS lens control or ELC for auto electronic shutter.
Move the cursor to the position shown in Fig. 4. The exposure level can be
adjusted by moving the LEVEL cursor on the menu accordingly.
ALC:
ALC MENU
LENS TYPE
DC
LENS LEVEL ----------*-----
BACK
ELC: Auto electronic shutter mode.
ELC MENU
LENS LEVEL ----------*-----
BACK
NOTE:
ELC mode is for use with fixed-iris lenses!
D/N MODE
AUTO
D/N LEVEL
HIGH
D/N DELAY
15 sec
EXPOSURE
<ALC>
SHUTTER
1/50
GAIN
NORMAL
SYNC
LL:000
BLC
OFF
NEXT EXIT CANCEL DEFAULT
Fig. 5
SHUTTER
This function sets the high-speed electronic shutter (AUTO to 1/100K sec).
Move the cursor to the position shown in Fig. 5.
Using the LEFT/ RIGHT button, select a shutter speed from 1/50 to 1/100K.
03.2005