Harris Intraplex STL-160 Series Installation & Operation Manual page 84

Intraplex stl-160, intraplex acs-160 series t1 multiplexer
Table of Contents

Advertisement

ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Table 4-3. CM-5RB Advanced Configuration Group Menu (continued)
Function
Group
TXYL
Off
On
Auto
ESF (Default)
exit
TYPE
VRM
T1 (Default)
exit
PRIM
TERM
DI-A
DI-B
SPAR
exit
PLL
Auto (Default)
Narr
Wide
exit
CUST
Std (Default)
KT
STL
FTI
4-10
Description
Transmit yellow alarm function
RED = not selected, GREEN = selected
Yellow alarm is off (never active)
Yellow alarm is on (always active)
Automatically sends yellow alarm
Automatically sends yellow alarm only in ESF
Exit TXYL and display TYPE
Multiplexer type. This function sets the basic multiplexer type
RED = not selected, GREEN = selected
Sets unit to run as a variable-rate multiplexer
Sets unit to run as an T1 multiplexer
Exit TYPE and display PRIM
Primary mode. This function sets the primary operating mode for the
CM-5RB module. When the common module is first plugged in, it
determines its mode based on the setting of the DIP switches on the
MA-215, MA-235-1, MA-235-2 or MA-217B module adapter. You can use
PRIM to override these switch settings.
RED = not selected, GREEN = selected
Sets the mode to terminal
Sets the mode to DI-A (drop and insert multiplexer)
Sets the mode to DI-B (drop and insert multiplexer)
Sets the mode to spare (inactive)
Exit PRIM and display PLL
Phase-locked loop filter. This function sets the bandwidth of the filter in
the phase-locked loop (PLL) used to derive the transmit timing from the
input T1. The PLL is used when the timing is set to loop, through, or
external.
RED = not selected, GREEN = selected
Determines the width based on the timing in use: narrow for loop or
external timing, wide for through timing.
Forces the setting to narrow
Forces the setting to wide
Exit PLL and display EIB
Customer application menu
RED = not selected, GREEN = selected
Standard alarm declaration criteria
Modified alarm criteria
Modified alarm criteria for use in studio-to-transmitter links (STLs)
Modified line criteria
4 – Setup & Configuration
Harris Corporation
Intraplex Products