Harris Intraplex STL-160 Series Installation & Operation Manual page 170

Intraplex stl-160, intraplex acs-160 series t1 multiplexer
Table of Contents

Advertisement

ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Connector
Consumption
Power Supply
Modules for
Three-Rack Unit
(3RU) Shelf
PSY60AC
(standard)
PSY5024
PSY5048
PSY100AC
Power Supply
Modules for One-
Rack-Unit (1RU)
Shelf
Signaling
Connector
7-4
On the rear panel of the multiplexer
For AC: 3-prong jack
For DC: Terminal strip (3RU shelves)
2.6 watts (3.6 watts w/module adapter) for each CM-5RB common module
(one in a terminal multiplexer, two in a dual terminal or drop/insert
multiplexer), plus channel module consumption
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 60 Watts
Nominal Input Voltage: -24 VDC
Input Voltage Range: -20 to -36 VDC
Input Fuse: 5A (slow blow)
Output Power: 50 Watts
Nominal Input Voltage: -48 VDC
Input Voltage Range: -40 to -72 VDC
Input Fuse: 5A (slow blow)
Output Power: 50 Watts
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 95 Watts
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 30 Watts
Voltage: -60 VDC maximum
Fuse: 2A Slow-blow, external (required)
On rear panel: terminal strip (3RU), or DB-15S alarm connector (1RU)
7 – Specifications
Harris Corporation
Intraplex Products

Advertisement

Table of Contents