5 – Remote Control
BAUD and PAR are both underscored, indicating that there is an additional menu layer beneath them
that contains more functions. BAUD and PAR may be thought of as subgroups within the SIO function
group. The Lock function is not underscored, indicating that it is a standard function and therefore
does not have an additional menu layer beneath it.
Table 5-2. SIO Group
Function
Setting
BAUD
110
(baud
300
rate)
1200
2400
4800
9600
19,2
57,6
exit
PAR
Spac
(parity)
Mark
Even
Odd
exit
Lock
When the Lock function is displayed, press up twice on the SET/NEXT switch to toggle the state of
the remote port between locked and unlocked. The green (top) light turns on when the port is
locked; the red (bottom) light turns on when the port is unlocked.
To exit the Lock function and display the BAUD subgroup, press down on the SET/NEXT switch. To
exit the SIO group, press up and down on the GROUP switch.
5.1.1.4
Baud Rate Setting
To display and change the current remote port baud rate:
1. Press down repeatedly on the GROUP switch until SIO appears.
2. Press down repeatedly on the SET/NEXT switch until the display reads BAUD.
3. Press up once on the SET/NEXT switch. The display now reads 110 which is the first available baud
rate, 110 bits per second (bps).
4. Press down on the SET/NEXT switch additional times to see the other available baud rates: 300,
1200, 2400, and so on. Note that the green (top) light turns on when the display shows the
currently set baud rate, and the red (bottom) light turns on when the display shows any other
baud rate.
5. To change the current baud rate, press down on the SET/NEXT switch until the display shows the
desired baud rate, and then press up twice on the SET/NEXT switch. After the first press the green
(top) light blinks, indicating that a change is about to be made. After the second press, the light
turns on continuously, indicating that the current baud rate now equals the displayed baud rate.
Harris Corporation
Intraplex Products
ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
110 bps
300 bps
1200 bps
2400 bps
4800 bps
9600 bps
19,2 kbps
57,6 kbps
When exit is displayed, press up on the SET/NEXT switch to exit the BAUD subgroup and
display the PAR function.
Space. No parity: all parity bits set to zero.
Mark. No parity: all parity bits set to one.
Even parity. Each parity bit is set so that the total number of ones in each data byte,
including the parity bit, is even.
Odd parity. Each parity bit is set so that the total number of ones in each data byte,
including the parity bit, is odd.
When exit is displayed, press up on the SET/NEXT switch to exit the PAR subgroup and
display the Lock function.