Harris Intraplex STL-160 Series Installation & Operation Manual page 131

Intraplex stl-160, intraplex acs-160 series t1 multiplexer
Table of Contents

Advertisement

5 – Remote Control
Table 5-12. Line/Module Redundancy ISiCL STATUS? Error Messages (continued)
Line/Module
Redundancy Mode
Note:
The next status conditions can only be generated if these conditions are all true:
FTI mode (from the advanced front panel select CUST->FTI) and ESF (Extended Superframe) Framing
Primary, Backup
Primary, Backup
Primary, Backup
After a module switch occurs due to a failed module, or after a module reversion switch occurs due to
replacement of a failed module with a good module, an ISiCL channel module status query may be
responded to with a "WAIT - SCANNING CHANNEL MODULES" response. During a module switchover,
the common module has an incomplete channel module status database. The common module
reacquires this database. This process may take a second or two to complete. During this time the
ISiCL "WAIT..." response is generated. ISiCL channel module configuration is not affected during a
module switchover.
After a module switch occurs due to an inactive module, the channel module ISiCL status is not
refreshed. All channel modules in the shelf are read to retrieve the most recent information. This
process may take a second or two. During this period, if a channel module status query is given, an
error message is generated:
:TERM:C5:STATUS?:;
<CR>
* WHAT?
WAIT - SCANNING CHANNEL MODULES;
5.2.3.7
Channel Module Configuration
To determine the configuration of a given channel module in an ACS-160 Series multiplexer, issue a
CONFIG? command in this form:
<Address>:Cn:CONFIG?:;
where n is the number of the target channel module. For example, to determine the setup of channel
module #4 in multiplexer #20, issue this command:
20:C4:CONFIG?:;
The response to a valid channel module CONFIG? command has this general form:
* OK
CHANNEL CARD nn, TYPE mmm
UNDER REMOTE (or LOCAL) CONTROL
SRVC = ON (or OFF)
(one or more lines stating the values of each "P" (setup) parameter);
Table 5-13 gives an example of a typical response to a CONFIG? command issued to a PT-153
program audio transmitter.
Harris Corporation
Intraplex Products
ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Shelf
Status
NORMAL
RECEIVE 86 ERRORED SECS IN 24 HOURS
Eighty-six or more errored seconds in a 24-hour window has occurred.
Note: Errored Second (ES) is defined in ATT 54016.
NORMAL
RECEIVE 5 ERRORED SECS IN 15 MINUTES
Five or more errored seconds in a 15-minute window has occurred.
Note: Errored Second (ES) is defined in ATT 54016.
NORMAL
RECEIVE 2 ERRORED SECS IN 15 MINUTES
Two or more errored seconds in a 15-minute window has occurred.
Note: Errored Second (ES) is defined in ATT 54016.
ISiCL "STATUS?" Error Message/Description
Version 2.11, August 2011
5-33