Harris Intraplex STL-160 Series Installation & Operation Manual page 136

Intraplex stl-160, intraplex acs-160 series t1 multiplexer
Table of Contents

Advertisement

ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Table 5-16. Explanation of CONFIG? Response for Example 2
Response
* OK
CHANNEL CARD 4, TYPE 202
UNDER REMOTE CONTROL
SRVC = OFF
P01 = 11 (B00001011)
P02 = 12 (B00001100)
P03 = 13 (B00001101)
P04 = 14 (B00001110)
P05 = 1 (B00000001)
P06 = 1 (B00000001)
P07 = 0 (B00000000)
P08 = 0 (B00000000)
P09 = 0 (B00000000)
P10 = 0 (B00000000);
Table 5-17 shows the four commands you enter.
Table 5-17. Commands to Change Channel Time Slot and Bandwidth
Command
7:C4:SET:P01 = 9;
7:C4:SET:P05 = 0;
7:C4:SET:P06 = 0;
7:C4:SET:P01 = 9;
After each command, the system responds
* OK;
To verify that the changes are correct, type
7:C4:CONFIG?:;
The system repeats its previous response. The second time slot for the left channel and both time
slots for the right channel have not been changed, and they show up on the configuration listing
with their old settings. This does not matter, because when the PT-150A module is configured to
transmit a single 7.5 kHz channel, only the first time slot on the left channel is active.
Turn the module back on with this command:
7:C4:SET:SRVC = ON;
Relock the remote port on the DI-A common module with the command:
7:DI-A:LOCK:;
The system responds
* OK;
The changeover is complete.
5-38
A valid query was received.
The module in slot 4 is a PT-153 module.
Set to remote control.
The module's output is disabled.
First left channel time slot is set to 11.
Second left channel time slot is set to 12.
First right channel time slot is set to 13.
Second right channel time slot is set to 14.
Set to 15kHz bandwidth.
Both left and right channels are active.
Left channel is set to 16-bit coding.
Right channel is set to 16-bit coding.
Set to transmit via the DI-A port.
The scrambler is off.
Meaning
Set the first left channel time slot to 9.
Set to 7.5kHz mode.
Set right channel to OFF.
Set to transmit via the DI-B port.
Meaning
5 – Remote Control
Harris Corporation
Intraplex Products

Advertisement

Table of Contents
loading