Installation Information - Whirlpool R-94 User Manual

“p” model air conditioner
Table of Contents

Advertisement

INSTALLATION INFORMATION

1.
Open the window and mark the centerline
of the inner sill.
Inner Sill
Room
Centerline
2.
Use two short screws, and attach the two
L-brackets 8˝ from both sides of the
centerline so they are flush against the
back of the inner sill, with the short side of
the bracket positioned vertically.
Inner Sill
Outer Sill
8"
(20.3 cm)
8"
(20.3 cm)
OUTSIDE
Excessive Weight Hazard
Use two or more people to move and
install the air conditioner.
Failure to do so can result in back, or
other injury.
Short Screws
INSIDE
Centerline
L-Brackets
IMPORTANT NOTES:
• Make sure that you maintain a good grip
on the air conditioner so that it does not
fall out of the window opening during the
installation.
• Make sure that you center the unit in the
window so that the L-brackets mate with
the bottom guides. If the unit is not cen-
tered properly, it could slide out of the
opening.
3.
Carefully lift the air conditioner, and center
it in the window opening, then slide it into
place so that the bottom guides drop into
the two L-brackets you installed in step 2.
Window Frame
Upper Guide
L-Bracket
Bottom Guide
4.
Lower the window sash so it is behind the
upper guide of the air conditioner. NOTE:
the back of the air conditioner should tilt
down slightly, as shown above.
2-1
Seal
about
1/4"
(6.3 mm)

Advertisement