FAN MOTOR REINSTALLATION NOTES:
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
1.
Make sure that you reconnect the green
ground wire to the same bracket location
as before (next to the power cable).
2.
Position the fan motor as shown in the
photo at the bottom of the previous page,
and mount the motor to the front air guide
with two black screws.
3.
Note that the fan hub hole has a "key"
inside it. Position this key over the flat of
the motor shaft, and slide the fan onto the
shaft until the end is approximately 1/4˝
from the outside of the fan hub hole.
4.
Squeeze the tabs on the ring clip and slide
the clip over the fan hub.
5.
Install the blower on the front fan motor
shaft as far as the "stop" at the end of the
hub opening, then install the ring clip over
the hub.