Basic software procedures
Initial Choose this option if the system board has been replaced prior to the
BMC update procedure. This option will perform all relevant flash
procedures in a row, including the BMC firmware and bootloader.
V
CAUTION!
Do not interrupt the BMC upgrade process after it has started. If the
process is interrupted, the BMC BIOS may be permanently corrupted.
I
If the BMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê After completion of the flash process, remove the USB stick and restart the
server.
BMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable BMC firmware update image.
Ê Ensure that the server has been shut down and disconnected from the
mains as described in section
Ê Connect the USB stick to the USB port.
I
Ensure that only the USB device with the BMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the BMC recovery state.
Ê Press the Power On / Off button. The system starts the POST process.
I
In BMC recovery mode, the "FUJITSU" logo does not show up.
Ê The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose the Recovery_L option from the update tool menu to start the BMC
update process.
80
"Shutting down the server node" on page
Upgrade and Maintenance Manual
41.
CX272 S1