Installing a Passive CPU Heatsink

To install the SNK-0022+ Passive Heatsink, use the following procedure:
Installing a SNK-0022+ Passive Heatsink
Note: Do not apply any thermal grease to the heatsink - the required amount has
already been applied.
1. Hold the heatsink and place the heatsink on top of the CPU so that the two
mounting holes are aligned with those on the retension mechanism.
2. Make sure the force of the screwdriver torsion is under 6.025 kgf-cm (5.23
lbs-in), and keep screw direction vertical.
3. Screw in two opposite screws until they are just snug (do not fully tighten
them yet).
4. Finish by fully tightening both screws after they are both in snug.
Note: see Chapter 6 for details on installing the air shroud.

Removing the Heatsink

Note: We do not recommend removing the CPU or the heatsink. If you do need
to remove the heatsink, please follow the instructions below to prevent damage to
the CPU or other components.
Removing a Passive Heatsink
1. Unplug the power cord from the power supply.
2. Remove air shroud from inside the chassis.
3. Loosen all screws from the mounting holes.
4. With all screws loosened, remove the heatsink from the CPU.