Supero A+ Server 1022TC-IBQF User Manual

A+ server
Table of Contents

Advertisement

Quick Links

S
UPER
®
A+ SERVER
1022TC-IBQF
1022TC-TF
USER'S MANUAL
Revision 1.0d

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A+ Server 1022TC-IBQF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Supero A+ Server 1022TC-IBQF

  • Page 1 UPER ® A+ SERVER 1022TC-IBQF 1022TC-TF USER’S MANUAL Revision 1.0d...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3: About This Manual

    SC808T-920B 1U rackmount chassis and the dual processor H8DCT-F (for the 1022TC-TF) and H8DCT-IBQF (for 1022TC-IBQF) serverboards. The only differ- ence between the two servers is that the 1022TC-IBQF server has an InfiniBand® port and the 1022TC-TF does not. Manual Organization...
  • Page 4 A+ Server 1022TC-IBQF/1022TC-TF User's Guide Chapter 4: Warning Statements for AC Systems You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the A+ Server 1022TC-IBQF/1022TC-TF. Chapter 5: Advanced Motherboard Setup Chapter 5 provides detailed information on the H8DCT-F/IBQF motherboard, including the locations and functions of connectors, headers and jumpers.
  • Page 5: Table Of Contents

    Preface Contents Chapter 1 Introduction Overview ......................1-1 Motherboard Features ..................1-2 Processor ......................1-2 Memory ......................1-2 Onboard SATA ....................1-2 PCI Expansion Slots ..................1-2 Onboard Controllers/Ports ................1-2 InfiniBand ....................... 1-2 Other Features ....................1-3 Server Chassis Features ................1-4 System Power ....................
  • Page 6 A+ Server 1022TC-IBQF/1022TC-TF User's Guide Checking the Serverboard Setup ..............2-8 Preparing to Power On ................... 2-9 Chapter 3 System Interface Overview ......................3-1 Control Panel Buttons ..................3-2 Control Panel LEDs ..................3-2 Overheating ..................... 3-3 Drive Carrier LEDs ..................3-4 Power Supply LEDs ..................
  • Page 7 Preface Installing Memory .................... 5-8 DIMM Module Population Configuration ..........5-10 Adding PCI Expansion Cards ................5-11 Motherboard Details ..................5-12 Connector Definitions ................... 5-14 Power Connectors ................... 5-14 Auxiliary Power Connector ............... 5-14 PW_ON Connector ................... 5-14 Reset Connector ..................5-14 Overheat/Fan Fail LED (OH)..............
  • Page 8 A+ Server 1022TC-IBQF/1022TC-TF User's Guide 5-11 Onboard Indicators ..................5-22 LAN1/LAN2 LEDs ..................5-22 Dedicated IPMI LAN LEDs ..............5-22 Power LED ....................5-22 UID LED (LE1) ..................5-22 5-12 SATA Drive Connections ................5-23 SATA Ports ....................5-23 5-13 Enabling SATA RAID ..................
  • Page 9: Chapter 1 Introduction

    Chapter 1 Introduction Overview The Supermicro A+ Server 1022TC-IBQF/1022TC-TF is a dual processor, 1U rackmount server. It is comprised of two main subsystems: the SC808T-920B chassis and two serverboards. The 1022TC-TF server uses two H8DCT-F serverboards; the 1022TC-IBQF uses two H8DCT-IBQF serverboards, the latter offering a QSFP Infiband port.
  • Page 10: Motherboard Features

    1022TC-IBQF/1022TC-TF User's Manual Motherboard Features At the heart of the A+ Server 1022TC-IBQF/1022TC-TF lies two H8DCT-F/IBQF dual processor motherboards based upon one AMD SR5670 chipset and one SP5100 Southbridge chipset. Below are the main features of the H8DCT-F/IBQF. Note that the features on each board are doubled for the server, which includes two nodes.
  • Page 11: Other Features

    Chapter 1: Introduction Other Features Other onboard features that promote system health include voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors and virus protection. Figure 1-1. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram and may not exactly represent the features on your motherboard.
  • Page 12: Server Chassis Features

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Server Chassis Features The following is a general outline of the main features of the SC808T-920B 1U twin rackmount server chassis. Details on the chassis can be found in Chapter 6. System Power The SC808T-920B chassis includes a single high-efficiency 920W power supply, which provides the power to both serverboards housed in the chassis.
  • Page 13: Contacting Supermicro

    Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel:...
  • Page 14 + Se ver 1022TC-IBQF/1022TC-TF User's Manual Notes...
  • Page 15: Chapter 2 Server Installation

    Preparing for Setup Decide on a suitable location for the rack unit that will hold the 1022TC-IBQF/1022TC-TF. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet.
  • Page 16: Warnings And Precautions

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual • This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices accord- ing to §2 of the the German Ordinance for Work with Visual Display Units.
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
  • Page 18: Installing The Server Into A Rack

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Installing the Server into a Rack This section provides information on installing the server into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6.
  • Page 19: Installing The Rack Rails

    Chapter 2: Server Installation Installing the Rack Rails The SC808 chassis includes a set of inner rack rails in two sections: inner rails and inner rail extensions. The inner rails are preattached and do not interfere with normal use of the chassis if you decide not to use a server rack. Attach the inner rail extensions to to the inner rails, to stabilize the chassis within the rack.
  • Page 20 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Installing the Outer Rails to the Rack 1. Attach the short bracket to the outside of the long bracket. You must align the pins with the slides. Also, both bracket ends must face the same direction.
  • Page 21: Installing The Server Into A Telco Rack

    Chapter 2: Server Installation Figure 2-4. Installing the Chassis into a Rack Installing the Server into a Telco Rack To install the server into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far the server will extend out the front of the rack.
  • Page 22: Checking The Serverboard Setup

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Checking the Serverboard Setup After you install the server in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made.
  • Page 23: Preparing To Power On

    Chapter 2: Server Installation Checking the Components and Setup 1. You may have processors already installed in each of the two serverboards. Each processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation. 2. Your server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots.
  • Page 24 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Providing Power 1. Plug the power cords from the power supplies unit into a high-quality power strip that offers protection from electrical noise and power surges. 2. It is recommended that you use an uninterruptible power supply (UPS).
  • Page 25: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview The chassis includes: • Two control panels on the front that include power buttons and status monitor- ing lights • Status lights on externally accessable hard drives • Status lights for the power supply visible from the back of the chassis Figure 3-1.
  • Page 26: Control Panel Buttons

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Control Panel Buttons The chassis includes two push-buttons that control power to the system. Reset: The reset button is used to reboot the system. Power: The main power switch is used to apply or remove power from the power supply to the server system.
  • Page 27: Overheating

    Chapter 3: System Interface NIC1: Indicates network activity on GLAN1 when flashing. HDD: Indicates IDE channel activity on the hard drive when flashing. Power: Indicates power is being supplied to the system power supply units. This LED should normally be illuminated when the system is operating. Overheating There are several possible responses if the system overheats.
  • Page 28: Drive Carrier Leds

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Drive Carrier LEDs The chassis includes externally accessable SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. • Green: When illuminated, this LED indicates drive activity. It blinks on and off when that particular drive is being accessed This function is controlled by the backplane.
  • Page 29: About Standardized Warning Statements

    Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 30 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 31 Chapter 4: Warning Statements for AC Systems ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬ ‫حىادث‬ ‫أي‬ ‫وقىع‬ ‫وٌع‬...
  • Page 32: Installation Instructions

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de...
  • Page 33: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 34: Power Disconnection Warning

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
  • Page 35 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 36: Equipment Installation

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
  • Page 37: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 38: Battery Handling

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .)'‫כלי אבטחה בלבד (מפתח, מנעול וכד‬ ‫محظورة‬ ‫مناطق‬ ٍ‫نتركُبها ف‬ ‫هذه انىحذة‬ ‫تخصيص‬ ‫تم‬ ،‫أداة خاصت‬ ‫من خالل استخذاو‬...
  • Page 39 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 40: Redundant Power Supplies

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 41: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 42: Comply With Local And National Electrical Codes

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫اللىحة‬ ‫أوالطاقة المىجىدة على‬ ‫التيار الكهزبائي‬ ‫مه‬ ‫خطز‬ ‫هناك‬ ‫هذا الجهاس‬ ‫خدمة‬ ‫كه حذرا عند‬ ‫يعمل‬ ‫النظام‬ ‫عندما يكىن‬...
  • Page 43: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫المتعلقة‬ ‫المحلية والىطىية‬ ‫قىاويه‬ ‫يجب أن يمتثل لل‬ ‫الكهربائية‬...
  • Page 44: Hot Swap Fan Warning

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 45 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 46: Power Cable And Ac Adapter

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only.
  • Page 47 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué...
  • Page 48 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Notes 4-20...
  • Page 49: Chapter 5 Advanced Motherboard Setup

    Chapter 5: Advanced Motherboard Setup Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install the H8DCT-F/IBQF motherboard into the chassis, connect the data and power cables and install add-on cards. All motherboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
  • Page 50: Unpacking

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Unpacking The motherboard is shipped in antistatic packaging to avoid electrical static discharge. When unpacking the board, make sure the person handling it is static protected. Motherboard Installation This section explains the first step of physically mounting the H8DCT-F/IBQF into the SC808T-920B chassis.
  • Page 51: Connecting Cables

    Chapter 5: Advanced Motherboard Setup Connecting Cables Now that the motherboard is installed, the next step is to connect the cables to the board. These include the data cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the flow of cooling air that moves through the system from front to back.
  • Page 52: Rear I/O Ports

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Figure 5-1. Control Panel Header Pins 20 19 Ground Power LED 3.3V HDD LED FP UID Switch/3.3VSB NIC1 (Activity) LED NIC1 (VCC) LED NIC2 (Activity) LED NIC2 (VCC) LED OH/Fan Fail/PWR Fail/UID LED Blue_LED_Cathode (UID)/5V SB Power Fail LED 3.3V...
  • Page 53: Processor And Heatsink Installation

    Chapter 5: Advanced Motherboard Setup Processor and Heatsink Installation Caution: Exercise extreme caution when handling and installing the processor. Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Installation Procedure Follow the procedures as listed below to install the motherboard into a chassis. 1.
  • Page 54 + Se ver 1022TC-IBQF/1022TC-TF User's Manual 3. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, carefully place the CPU into the socket. Do not drop the CPU on the socket, move the CPU horizontally or vertically or rub the CPU...
  • Page 55: Installing A Passive Cpu Heatsink

    Chapter 5: Advanced Motherboard Setup Installing a Passive CPU Heatsink To install the SNK-0022+ Passive Heatsink, use the following procedure: Installing a SNK-0022+ Passive Heatsink Note: Do not apply any thermal grease to the heatsink - the required amount has already been applied.
  • Page 56: Installing Memory

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Installing Memory Installing Memory 1. Insert each memory module vertically into its slot, paying attention to the notch along the bottom of the module to prevent inserting the module incorrectly (see Figure 5-4). 2. Install to slots P1/DIMM1A, P1/DIMM2A, etc. For best performance always install in groups of two and in the numerical order of the DIMM slots.
  • Page 57 Chapter 5: Advanced Motherboard Setup Figure 5-3. Installing DIMM into Slot To Install: Insert Notch Notch module vertically and press down until it snaps into place. Pay Front View attention to the align- ment notch at the bottom. Note: Notch should align with the receptive key point on To Remove: Use the slot.
  • Page 58: Dimm Module Population Configuration

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual DIMM Module Population Configuration For memory to work properly, follow the tables below for memory installation: Per Channel DIMM Populations Options Max. MHz, 1.5V Max. MHz, Max. GB/ DIMM Type DIMM A DIMM B...
  • Page 59: Adding Pci Expansion Cards

    Chapter 5: Advanced Motherboard Setup Adding PCI Expansion Cards The 1022TC-IBQF/1022TC-TF includes two preinstalled riser cards designed to support two low-profile PCI Express x16 cards to fit inside the chassis. Installing an Expansion Card 1. After powering down the system, remove the PCI slot shield.
  • Page 60: Motherboard Details

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Motherboard Details See the Figure 5-4 for a layout of the H8DCT-F/IBQF motherboard. H8DCT-F/IBQF Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 5-10) JIB1 InfiniBand Enable/Disable (H8DCT-IBQF only) Pins 1-2 (Enabled)
  • Page 61 Chapter 5: Advanced Motherboard Setup Figure 5-4. H8DCT-IBQF Motherboard Layout (not drawn to scale) COM1 JIB1 Speaker JPG1 SR5670 JBT1 SP5100 SATA0 Battery SATA1 SATA2 SATA3 CPU1 CPU2 FAN3 FAN1 FAN2 Note: Jumpers not indicated are for test purposes only. 5-13...
  • Page 62: Connector Definitions

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Connector Definitions Proprietary 20-pin Connector Pin Definitions Pin# Definition Pin # Definition Power Connectors PS_ON_N The proprietary power supply connector 5V_STBY (JPW1 and JPW2) meets the SSI (Superset ATX) 20-pin specification. Refer to the table below for the pin definitions of the ATX 20-pin power connector.
  • Page 63: Nic2 (Lan2) Led

    Chapter 5: Advanced Motherboard Setup NIC2 (LAN2) LED NIC2 LED Pin Definitions The LED connections for LAN2 are on pins (JF1) 9 and 10 of JF1. Attach LAN LED cables to Pin# Definition display network activity. See the table on the right for pin definitions.
  • Page 64: Serial Ports

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Serial Ports Serial Port Pin Definitions (COM1) The COM1 serial port is located beside the Pin # Definition Pin # Definition VGA port. See the table on the right for pin definitions. Ground Note: NC indicates no connection.
  • Page 65: Ipmb

    Chapter 5: Advanced Motherboard Setup IPMB IPMB Pin Definitions A System Management Bus header for the Pin# Definition IPMI slot is located at IPMB. Connect the Data appropriate cable here to use the IPMB I2C Ground connection on your system. Clock No Connection Trusted Platform Module Header...
  • Page 66: T-Sgpio

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual T-SGPIO T-SGPIO Header Pin Definitions (T-SGPIO1) The T-SGPIO1 (Serial General Purpose Pin# Definition Pin # Definition Input/Output) headers provide a bus between Data the SATA controller and the backpane Ground Data to provide SATA enclosure management functions.
  • Page 67: 5-10 Jumper Settings

    Chapter 5: Advanced Motherboard Setup 5-10 Jumper Settings Connector Pins Explanation of Jumpers To modify the operation of the motherboard, Jumper jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Setting of the connector.
  • Page 68: Infiniband Port Enable/Disable (H8Dct-Ibqf Only)

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual InfiniBand Port Enable/Disable InfiniBand Port (H8DCT-IBQF only) Jumper Enable (JIB1) Jumper Settings JIB1 enables or disables the InfiniBand port Jumper Setting Definition on H8DCT-IBQF serverboard. The default Pins 1-2 Enabled position is on pins 1 and 2 to enable the...
  • Page 69: Watch Dog Enable/Disable

    Chapter 5: Advanced Motherboard Setup Watch Dog Enable/Disable Watch Dog Jumper Settings (JWD1) JWD1 enables the Watch Dog function, a Jumper Setting Definition system monitor that takes action when a Pins 1-2 Reset software application freezes the system. Pins 2-3 Jumping pins 1-2 will have WD reboot the system if a program freezes.
  • Page 70: 5-11 Onboard Indicators

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual 5-11 Onboard Indicators LAN LED (Connection Speed Indicator) LAN1/LAN2 LEDs LED Color Definition The Ethernet ports (located beside the Serial 10 MHz port) have two LEDs. On each Gb LAN port, Green 100 MHz...
  • Page 71: 5-12 Sata Drive Connections

    Chapter 5: Advanced Motherboard Setup 5-12 SATA Drive Connections SATA Ports SATA Ports Pin Definitions There are no jumpers to configure the SATA (SATA0-SATA3) ports, which are designated SATA0 through Pin # Definition SATA3. See the table on the right for pin Ground definitions.
  • Page 72: 5-13 Enabling Sata Raid

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual 5-13 Enabling SATA RAID Now that the hardware is set up, you must install the operating system and the SATA RAID drivers, if you wish to use RAID with your SATA drives. The installation procedure differs depending on whether you wish to have the operating system installed on a RAID array or on a separate non-RAID drive.
  • Page 73: Enabling Sata Raid In The Bios

    Chapter 5: Advanced Motherboard Setup Enabling SATA RAID in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the <Delete> key to enter the BIOS Setup Utlility. After the setup utility loads, 1.
  • Page 74 + Se ver 1022TC-IBQF/1022TC-TF User's Manual Figure 5-6. DotHill RAID Utility Program Screen Figure 5-7. Adaptec RAID Utility Program Screen Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to define the drives you want to include in the RAID array and the mode and type of RAID.
  • Page 75: Installing The Raid Driver During Os Installation

    Chapter 5: Advanced Motherboard Setup Installing the RAID Driver During OS Installation You may also use the procedure below to install the RAID driver during the Windows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the system.
  • Page 76 + Se ver 1022TC-IBQF/1022TC-TF User's Manual Figure 5-8. Driver/Tool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time.
  • Page 77: Superdoctor Iii

    Chapter 5: Advanced Motherboard Setup Figure 5-9. SuperDoctor III Interface Display Screen (Health Information) Figure 5-10. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.
  • Page 78: 5-15 Serverboard Battery

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual 5-15 Serverboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-11). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
  • Page 79: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC808 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 80: Control Panel

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Figure 6-1. Chassis Front View Control Panel: Primary Control Panel: Secondary Serverboard Serverboard SATA Drives Figure 6-2. Chassis Rear View IPMI PCI-E x16 Power IPMI PCI-E x16 Port Ports Slot Supply Port Ports Slot InfiniBand...
  • Page 81: Drive Installation And Removal

    Chapter 6: Advanced Chassis Setup Drive Installation and Removal Hard disk drives can be installed or replaced without accessing the inside of the chassis. Note: Your operating system must include RAID support to enable the hot-swap capability of the drives. Drive Installation The hard disk drives are mounted in drive carriers to simplify their installation and removal from the chassis.
  • Page 82 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Installing a Hard Drive into a Hard Drive Carrier 1. Remove the two screws securing the dummy drive to the carrier. 2. Remove the dummy drive from the carrier. Dummy Drive Drive Carrier Figure 6-4. Removing the Dummy Drive from the Carrier 3.
  • Page 83: System Fans

    Chapter 6: Advanced Chassis Setup Installing a Hard Drive Carrier into the Chassis 1. Insert the loaded hard drive carrier into the drive bay of the chassis 2. Push the drive carier into the drive bay, pushing in the handle of the drive carrier until it clicks into the locked position.
  • Page 84 A+ Server 1022TC-IBQF/1022TC-TF User's Manual Changing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan has failed. (Never run the server for an extended period of time with the chassis open.) 2.
  • Page 85: Air Shrouds

    Chapter 6: Advanced Chassis Setup Air Shrouds Air shrouds channel air flow from the fans to cool components. Figure 6-8. Installing the Air Shrouds Power Supply The chassis has a single 920 watt power supply, capable of operating at 100 - 240 input volts.
  • Page 86: Replacing The Power Supply

    A+ Server 1022TC-IBQF/1022TC-TF User's Manual Replacing the Power Supply Installing a Power Supply 1. Power down both system nodes with the main power buttons on the control panel, then unplug the AC power cord. 2. Push the release tab on the back of the power supply as illustrated.
  • Page 87: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMIBIOS™ Setup utility for the H8DCT-F/IBQF serverboard. The 16 Mb AMI BIOS® is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
  • Page 88: Main Menu

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Main Menu When you first enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys.
  • Page 89: Processor And Clock Options

    Chapter 7: BIOS Wait for F1 if Error This setting controls the system response when an error is detected during the boot sequence. When enabled, BIOS will stop the boot sequence when an error is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu.
  • Page 90: Advanced Chipset Control

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual GART Error Reporting This option should remain disabled for normal operation. The driver developer may enable this option for testing purposes. Options are Enabled or Disabled. Microcode Update This setting Enables or Disables microcode updating.
  • Page 91: Ecc Configuration

    Chapter 7: BIOS CS Sparing This setting will reserve a spare memory rank in each node when enabled. Options are Enabled and Disabled. Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode.  ECC Configuration ECC Mode This submenu affects the DRAM scrub rate based on its setting.
  • Page 92: Southbridge Configuration

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual  SouthBridge Configuration OHCI/EHCI HC Device Functions These settings allow you to either Enable or Disable functions for OHCI or EHCI bus devices. USB 2.0 Controller Mode Use this setting to configure the USB 2.0 Controller in either Hi-Speed (480 Mps) or Full Speed (12 Mps) mode.
  • Page 93 Chapter 7: BIOS Block (Multi-Sector Transfer) Block mode boosts IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if block mode is not used. Block mode allows transfers of up to 64 KB per interrupt. Select "Disabled"...
  • Page 94 + Se ver 1022TC-IBQF/1022TC-TF User's Manual IDE Detect Timeout (Sec) Use the +/- keys to adjust and select the time out for detecting ATA/ATAPI devices. The default value is 35.  PCI/PnP Configuration Clear NVRAM Select Yes to clear NVRAM during boot-up. The options are Yes and No.
  • Page 95: Superio Device Configuration

    Chapter 7: BIOS Boots Graphic Adapter Priority This option specifies the priority for booting the graphic adapter for Onboard VGA or Offboard VGA.  SuperIO Device Configuration Serial 1 Address This option specifies the base I/O port address and Interrupt Request address of serial port 1.
  • Page 96: Hardware Health Configuration

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Flow Control Selects the flow control to be used for console redirection. Options are None, Hardware and Software. Redirection After BIOS POST Options are Disable (no redirection after BIOS POST), Boot Loader (redirection during POST and during boot loader) and Always (redirection always active).
  • Page 97 Chapter 7: BIOS CPU Temperature Display (CTD) CPU Temperature descriptions are defined as: Low  [Tctl Value = Lowest Value, Tctl Value = -45] Medium  [Tctl Value = -46, Tctl Value = 60] High  [Tctl Value = -61 and Above] Note: Only CPU temperature (Low, Medium, High) and system temperature (RT1) are required to be displayed in BIOS and in-system monitoring software.
  • Page 98: Acpi Configuration

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual • All system fans are required to be returned to a normal, non-CPU-overheating LFSC condition. Condition When a CPU is overheating Front Panel Overheating LED On and Solid Red Onboard Buzzer or Speaker On and Continuous Sound...
  • Page 99: View Bmc System Event Log

    Chapter 7: BIOS  View BMC System Event Log Pressing the Enter key will open the following settings. Use the "+" and "-" keys to navigate through the system event log. Clear BMC System Event Log Selecting this and pressing the Enter key will clear the BMC system event log. ...
  • Page 100: Security Menu

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Gateway Address In the field provided here enter the Gateway address in the decimal form of xxx.xxx.xxx.xxx with xxx having a value of less than 256 and in decimal form only. The current Gateway address in the BMC is shown.
  • Page 101: Boot Menu

    Chapter 7: BIOS Boot Sector Virus Protection This option is near the bottom of the Security Setup screen. Select "Disabled" to deactivate the Boot Sector Virus Protection. Select "Enabled" to enable boot sector protection. When "Enabled", AMI BIOS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard disk drive.
  • Page 102: Exit Menu

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Network Drives This feature allows you to specify the boot sequence from the list of available Network drives. A device that is in parenthesis has been disabled in the corresponding type menu. Retry Boot Devices This option allows you to retry boot devices.
  • Page 103: Appendix A Post Error Beep Codes

    Appendix A: POST Error Beep Codes Appendix A POST Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 104 + Se ver 1022TC-IBQF/1022TC-TF User's Manual Notes...
  • Page 105: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Note: Unless noted specs apply to a complete system (both serverboards). Processors Two AMD Opteron 4000 series processors in AMD Socket C32 type sockets per node Note: Refer to our website for details on supported processors. Chipset One AMD SR5670 chipset and one SP5100 Southbridge chipset per node BIOS...
  • Page 106: System Cooling

    + Se ver 1022TC-IBQF/1022TC-TF User's Manual Weight Gross Weight: 40 lbs. (18.2 kg.) System Cooling Three 4cm compound fans per node, each with a pair of counter-rotating fans System Input Requirements AC Input Voltage: 100 - 240V AC auto-range Rated Input Current: 13 - 4A max...
  • Page 107 Appendix B: System Specifications Notes...
  • Page 108 + Se ver 1022TC-IBQF/1022TC-TF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

This manual is also suitable for:

A+ server 1022tc-tf

Table of Contents