※Cautions for consisting MPDP System

The number of Daisy chain connection
- T heimagequalitycanbevarydependonthequalityofsignalandcable
condition.
INPUT SOURCE
Resolution
DVI
1600x1200x60HZ
RS-232C
- I fyouneedtousemoreMPDPsetsthanindicatedinthetable,usingaDVI
distributorishighlyrecommended.
Cautions for using Wall controller and Application devices
- I fyouuseMVP,Crestron,Extron,AMX,orJupitordevicesinsteadofMSCS,MPDP
ControlProgram,toconsistmultiscreen,APLfunctionmustbeturnedoffto
preventpossiblebrightnessdifferencebetweensets.
Caution for the other control program besides MPDP
Control Program (MSCS)
- I fyouwanttouseautomaticpoweron/offfunctionthatmakeMPDPturnedon/
offbyconnectingmainpower,allowatleast20secondsofStand-bytimebefore
MPDPisturnedon,whenyoumakecontrolprogram.
- B ICfunctionrequirestwo-waycommunication.IfyoudonotuseMSCS,therewill
bewhitebalancedifferencebyglobaldataastimeelapses.Toavoidsucherror,
NewMFCmustbeused.
- I fRS-232Ccommunicationsignalorotherimagesignalisappliedto9ormore
setssimultaneously,communicationalerrormayoccur.(Poweron&Broadcast)

Connection
Remark
6sets
HDCPAvailable
30sets
ORIONCableOnly
- 4 -
Environmental condition for installation
- S inceMPDPpanelisverysensitiveforphysicalimpact,installationrequires
considerablecaution.
- M inimumclearance(20cm)mustbesecuredforsmoothventilation.(SeeP14~15)
Installationmustavoidairtightornearairtightplaces.Improperventilationcauses
malfunctionandshortensproductlifetimebyrapidinternaltemperaturerise.If
MPDPhastoinstalledattheimproperventilation,additionalventilationopenings
orfansmustbeprovidedtokeeptheinternaltemperaturebetween0~35℃.
- F orgroundofMPDPandapplicationdevices,itshouldbeconnectedasframe
ground.
- C onsideringMPDPMaxpowerconsumption,checkthemainelectric
specification.
Consideration for easier service
- W henyoudesigntheexteriordesignforMPDPsystem,considereasier
disassemblyforpossibleserviceoccasioninthefuture.
-TheslidingUniversalUnitofORIONPDPisrecommendedforeasierservice.
- I fservicepeoplecanstepintothebacksideofMPDPsystem,itcangreatly
reducetimeandeffortforservice.
- I ncaseofhigherlocations,considertheinstallationlocationandexteriordesign
foreasierservice.