*IDrange(Program):0x01(1)~0xFF(255)
*M/S:SinceitisonlyMaster,"0x01"Valuemustbetransmitted.
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
*ElapsedTime
-Hundredthousands,tenthousands,thousands,hundreds,tens,ones:0(0x00)~9(0x09)rangevalue.
-
"Elapsed Time" Communication Sequence
*Waitfor500msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
Elapsed Time Command transmission (to Master)
3.12.
iP Serial number
-
Command for assigning and identifying the serial numbers of each IP board. (8 digit)
CMD: 0x75 (Get S/N), 0x76 (Set S/N)
-
Send to MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
* " Get/SetIPSerialNumber"(0x75/0x76)commandisnotapplicableas"Broad-cast"command,becauseeachPDPshouldhavean
uniqueserialnumber.
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x0A
Variable
0
1st
Variable
Variable
Variable
*IDrange(Program):0x01(1)~0xFF(255) 
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
*ElapsedTime
-0,1st,2nd,3rd,4th,5th,6th,7th:0(0x00)~9(0x09)rangevalue
-
"Elapsed Time" Communication Sequence
*Waitfor500msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*TheserialnumbercanbesavedinanyoneofMasterorSlave.
Elapsed Time Command transmission
(to Master or Slave)
Elapsed Time Response transmission (from Master)
Data
ETX
ID
M/S
Variable
Variable
0x03
Data
Check
Sum
ID
M/S
Elapsed Time
Variable
...
Variable
2nd
3rd
4th
5th
6th
Variable
Variable
Variable
Variable
Variable
*M/S:Master(0x01),Slave(0x00)
Elapsed Time Response transmission
(from Master or Slave)
- 68 -
3.13.
Default Data Load (Picture Control Data)
-
Initialize the PDP set. All the settings will be returned to the initial condition prior to the adjustment in the factory.
Pre-programmed value will be applied.
-
It is available only on Power On (Operative) status.
-
Since previous Picture Control Data will be lost with this command. High caution is required.
-
Send to MPDP
A.
NormalCommand
Value
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
B.
BroadcastCommand
Value
*MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MPDP
Value
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
ETX
-
"Default Data Load" Communication Sequence
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
0x03
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*ExceptforBroadcastcommand
7th
Default Data Load Command transmission
3.14.
BiC (Burn-in Compensation): Only Master
-
BIC function helps reducing burn-in effect. Please refer to User manual for further explanation.
-
It is available only on Power On (Operative) status.
-
Send to MPDP
A.
"Set"commandfrom"Get/Set"in"Data"area
Value
Infinitely Expandable
Data
STX
CMD
Length
ID
0x02
0x81
0x02
Variable
STX
CMD
Length
Data: ID
0x02
0x81
0x01
Variable
Data
STX
CMD
Length
ID
0x02
0x81
0x02
Variable
Default Data Load Response transmission
(to Master or Slave)
STX
CMD
Length
ID
M/S
0x02
0x6A
0x09
Variable
Variable
Value bit
Variable
Value3
Variable
- 69 -
ETX
M/S
Variable
0x03
ETX
0x03
Check Sum
ETX
M/S
Variable
Variable
0x03
(from Master or Slave)
Data
ETX
Setting Values
...
0x03
Get/Set
Address
Value
0x00
Variable
...
Value2
Value1
Value0
Variable
Variable
Variable

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opm-4250r

Table of Contents