"Power On" Communication Sequence
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*Commandsequence:SlaveMaster.(ExceptforBroadcastcommand)
Power On Command transmission (to Slave)
Power On Command transmission (to Master)
3.2.
Power Off
-
Command for Power Off : Stand-by status
-
It is available only during Power On (Operative) status.
-
Send to MPDP
A.
Normalcommand
STX
CMD
Length
Value
0x02
0x41
0x02
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
B.
Broadcastcommand
STX
CMD
Length
Value
0x02
0x41
0x01
*MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
0x41
0x02
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
*Checksum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
-
"Power Off" Communication Sequence
*Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand.
*Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission.
*Commandsequence:SlaveMaster.(ExceptforBroadcastcommand)
Power Off Command transmission (to Master)
Power Off Command transmission (to Slave)
Power On Response transmission (from Slave)
Power On Responsetransmission (from Master)
Data
ETX
ID
M/S
Variable
Variable
0x03
Data: ID
ETX
0x00
0x03
Data
Check Sum
ETX
ID
M/S
Variable
Variable
Variable
0x03
Power Off Response transmission (from Master)
Power Off Response transmission (from Slave)
- 60 -
3.3.
Multi-Scale
-
Command for expanding the screen of MPDP.
-
It is available only on Power On (Operative) status.
-
CMD: 0xDD (DVI 1), 0xEF (DVI 2)
-
Send to MPDP
A.
Normalcommand
STX
CMD
Length
Value
0x02
Variable
0x04
*IDrange(Program):0x01(1)~0x64(100)
*M/S:Master(0x01),Slave(0x00)
*XY:Thenumberofhorizontalaxis(X)/thenumberofverticalaxis(Y);upper4bits-X(Max:15),Lower4bits-Y(Max:15)
*P:thelocationofexpandedscreen
B.
Broadcastcommand
STX
CMD
Length
Value
0x02
Variable
0x04
*ID:0x00
*XY:ThenumberofMPDPsetsinhorizontalline(X),thenumberofMPDPsetsinverticalline(Y)
Thetop4bits-X(Max:15),thebottom4bits-Y(Max:15)
1:1screenratio(Fullscreen)is"0x11"
*S:TheIDofMPDPtobeexpandedintopleftposition,1:1screenratio(Fullscreen)is"0x00"
*X:ThenumberofallMPDPsetsinhorizontalline,1:1screenratio(Fullscreen)is"0x01"
*MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
Broadcastcommand:e.g.)Incaseof5x5MPDPformation
1
13
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
0x02(STX)
0xDD(CMD)
0x04(Length)
0x00(ID)
-
Receive from MPDP
STX
CMD
Length
Value
0x02
Variable
0x02
*IDrange(Program):0x01(1)~0xFF(255)
*M/S:Master(0x01),Slave(0x00)
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
Infinitely Expandable
Data
ETX
ID
M/S
XY
P
Variable
Variable
Variable
Variable
0x03
Data
ETX
ID
M/S
XY
P
0x00
Variable
Variable
Variable
0x03
4
11
0x33(XY)
0x01(S)
0x05(X)
0x03(ETX)
0x33(XY)
0x0D(S)
0x05(X)
0x03(ETX)
0x22(XY)
0x04(S)
0x05(X)
0x03(ETX)
0x41(XY)
0x0B(S)
0x05(X)
0x03(ETX)
0x11(XY)
0x00(S)
0x01(X)
0x03(ETX)
Data
Check Sum
ETX
ID
M/S
Variable
Variable
Variable
0x03
- 61 -