Basic System Description - Omron 3G3AX-MX2-PRT-E User Manual

Mx2/rx profibus option board
Hide thumbs Also See for 3G3AX-MX2-PRT-E:
Table of Contents

Advertisement

Basic System Description

2-1-3
LED Indicators
Table 2 LED Indicators
Indicator
Colour
RUN
Green
(Unit status)
ERR
Red
(Unit error)
BF
Red
(Bus Fail)
COMM
Green
(Comms status)
2-2
Basic System Description
PROFIBUS DP-V1 Master
Engineering Station
Engineering Station
For setting, monitoring and operation)
(For setting, monitoring and operation)
Four LED indicators (B) allow easy diagnosis. An attached grounding cable
(E) is sized to reach the ground terminals on all Inverter models. A feature in
the housing (F) will retain the mounting screw (G) when the Option Board is
not mounted to the Inverter. The orientation of the Fieldbus connector (D)
allows unstrained connection and removal of the PROFIBUS connector.
Please pay special attention to the Option Board connector: It must be prop-
erly connected with the Inverter when the Option Board is mounted.
The LED indicators on the front indicate the operational mode and status of
the Option Board and the network.
Status
OFF
No power or not yet ready for operation
Flashing Operating in commissioning mode
ON
Normal operation
ON
Fatal error
Flashing Operational error
OFF
No error
ON
No communication with PROFIBUS Master
Flashing Unsupported parameters or module configuration received from PROFIBUS Master
OFF
Communicating with PROFIBUS Master
ON
Cyclic data exchange or PROFIBUS diagnostics operational
OFF
No cyclic data exchange or PROFIBUS diagnostics
Refer to Section 5-1 for Troubleshooting using the LED indicators on page 57
PROFIBUS DP-V1 Master
PLC
PLC
The Option Board connects to the Master via a PROFIBUS network cable.
Inverter I/O data is generally shared with the Master's I/O memory through the
PROFIBUS DP network. Every PROFIBUS communication cycle, Inverter I/O
data is collected by the Option Board and exchanged with the Master. The
Engineering Station allows you to configure, monitor, program, diagnose and
operate the system.
Meaning
PROFIBUS
PROFIBUS
Section 2-2
MX2-A @ Inverter +
Inverter + Option Board
Option Board
Slave
Slave
9