Figure 5.12 Execution Example Of Read Multiple Command - Fujitsu MHW2120BK Maintenance Manual

Fujitsu internal hard drive product/maintenance manual
Table of Contents

Advertisement

Interface
Host

Figure 5.12 Execution example of READ MULTIPLE command

Error reporting conditions
(1) A specified address exceeds the range where read operations are allowed
(ST = 51h, ER = 10h).
(2) The range where read operations are allowed will be exceeded by an address
during a read operation (ST = 51h, ER = 10h).
(3) An uncorrectable disk read error occurred (ST = 51h, ER = 40h).
(4) The sync byte indicating the beginning of a sector was not found
(ST = 51h, ER = 01h).
(5) The READ MULTIPLE command is disabled (ST = 51h, ER = 04h).
(6) A SATA communication error occurred (ST = 51h, ER = 0Ch).
(7) An error other than the above errors occurred (ST = 51h, ER = 04h).
5-90
Reg. HD
PIO Setup
Data
Block
(4 sectors)
PIO Setup
Data
Block
(4 sectors)
PIO Setup
Data (1sector)
Partial
Block
Device
C141-E261