N If the Reset button is continuosly held down, every three seconds the LED pulses
(blinks) and puts the unit in a different mode. The Mode 5 LED blinks three
times, the third blink indicating that it is the last mode. The following modes are
separate functions, not a continuation from Mode 1 to Mode 5.
Reset Mode Comparison/Summary
Mode Activation
1
Hold down the recessed
Reset button while applying
power to the IPL T S unit.
After a mode 1 reset
is performed, update the
unit's firmware to the latest
version. Do not operate the
unit's firmware version that
results from the mode 1
reset. If you want to use the
factory default firmware,
you must upload that
version again.
2
Press and release the Reset
button. Within 2 seconds
type +++ on the keyboard.
N If the three "+'s"
(+++) are not enetered in
the 2-second time frame, the
COM port becomes a
control port only.
3
Hold down the Reset button
for about 3 sec. until the
Reset LED blinks once, then
press Reset momentarily
(<1 sec.) within 1 second.
4
Hold down the Reset button
for about 6 sec. until the
Reset LED has blinked
twice (once at 3 sec., again
at 6 sec.). Then press Reset
momentarily (for <1 sec.)
within 1 second.
5
Hold down the Reset button
for about 9 sec. until the
Reset LED has blinked three
times (once at 3 sec., again
at 6 sec., again at 9 sec.).
Then press Reset
momentarily (for <1 sec.)
within 1 second.
Result
The unit reverts to the factory default
firmware. Event scripting will not start if
the unit is powered on in this mode. All
user files and settings (drivers,
adjustments, IP settings, etc.) are
maintained.
If you do not want to update
firmware, or you performed a mode 1 reset
by mistake, cycle power to the unit to
return to the firmware version that was
running prior to the mode 1 reset. Use the
0Q SIS command to confirm that the
factory default firmware is no longer
running (look for asterisks following the
version number.)
The connected COM port becomes a
console port to send SIS commands.
Scripting remains on.
Mode 3 turns events on or off. During
resetting, the Reset LED flashes 2 times if
events are starting, 3 times if events are
stopping.
Mode 4
• Enables ARP capability.
• Sets the IP address back to factory
default (192.168.254.254).
• Sets the subnet back to factory default.
• Sets the default gateway address back
to the factory default.
• Sets port mapping back to factory
default.
• Turns DHCP off.
• Turns events off.
The Reset LED flashes 4 times in quick
succession during the reset.
Mode 5 performs a complete reset to
factory defaults (except the firmware).
• Does everything mode 4 does.
• Resets almost all the real time
adjustments: all audio settings, limit
initial power up volume, power
up/down delay, auto power down, and
misc. options. This does not affect an
optional MLS switcher, however.
• Clears driver-port associations and port
configurations (IR/RS-232).
• Removes button configurations.
• Resets all IP options.
• Removes scheduling settings.
• Removes/clears all files from switcher.
The Reset LED flashes 4 times in quick
succession during the reset.
IPL T S Series • Installation and Operation
Purpose/Notes
Use mode 1 to revert
to the factory default
firmware version if
incompatibility issues
arise with
user-loaded firmware.
Mode 2 enables the
SIS console port.
Mode 3 is useful for
troubleshooting.
Mode 4 enables you
to set IP address
information using
ARP and the MAC
address.
Mode 5 is useful if
you want to start over
with configuration
and uploading, and
also to replace events.