12.ERROR CODE (Cont.)
Error Code
3B20-3B22
3B30-3B32
3B40-3B42
3C10-3C13
3C20-3C22
3C30-3C32
3C40-3C42
3C50-3C52
3C60-3C62
9
3C70
3D10
3D20
3D30
3E10
3E20
214
9.JOB STATUS
Cause & Message
Context-Type error
Invalid character set
E-mail decode error
TIFF analysis error
TIFF compression error
TIFF resolution error
TIFF paper size error
Offramp transmission error
Offramp security error
Power failure
Destination address error
Exceeding maximum offramp
destinations
Fax unit is not installed
POP3 server communication error
POP3 server communication timeout
Corrective Action
Ask the sender to resend the E-mail with
attached files that are the TIFF format.
Ask the sender to resend the E-mail in the
ISO-8559-1/2 format.
Ask the sender to resend the E-mail.
Ask the sender to resend the E-mail with
attached files that are the TIFF format.
Ask the sender to resend the E-mail with
attached TIFF files in the MH, MR, MMR, or
JBIG compression.
Ask the sender to resend the E-mail with
attached TIFF files whose resolution is either
200 x 100, 200 x 200, 200 x 400, 300 x 300, or
400 x 400 dpi.
Ask the sender to resend the E-mail with
attached TIFF files that can be printed on the
paper available for this equipment.
Ask the sender to specify the correct fax
numbers and resend the E-mail.
Confirm the fax numbers that are specified in
the received offramp gateway job and ask the
sender to resend the E-mail with correct fax
numbers.
Confirm the job is recovered or not. If not, ask
the sender to resend the E-mail.
Ask your administrator whether the DNS and
mail server settings are correctly set. If they
are correctly set, ask the sender to confirm the
destination address is correct.
Ask the sender to specify up to 40 destinations
for one offramp gateway job. The equipment
cannot perform the offramp gateway
transmission for more than 40 destinations.
Make sure the Fax unit is installed, or
connected correctly.
Ask your administrator that the POP3 server
address is correctly set, or the POP3 server
works properly.
Ask your administrator that the POP3 server
works properly and the LAN cable is
connected to the server.