If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
1. For a wall control installation you will need a three-
wire (with ground) conductor cable between the
ceiling and wall outlet boxes. This will allow you to
control the fan separately from the lights. Figure 12
is a basic wiring diagram that will control the uplight
and downlight on a switch and the fan on a separate
control. Refer to the installation instructions and
wiring diagrams supplied with the Emerson Fan
Control Owner's Manual.
a. Connect the green grounding lead from the
hanger ball and the green grounding lead from
the hanger bracket to the grounding conductor
of supply (this may be a bare wire or a wire with
green colored insulation). Securely connect
wires with wire connector supplied.
b. Securely connect the white wire from the
downrod to the supply white (neutral) wire using
wire connector supplied. Securely connect the
black wire from the downrod to the supply black
(hot) wire using wire connector supplied.
c. Securely connect the blue wire from the
downrod to the supply red (hot) wire using wire
connector (supplied). After connections have
been made, turn leads upward and carefully
push leads into the outlet box, with the white and
green leads on one side of the outlet box and
the black, blue and yellow leads on the other
side of the outlet box.
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

5. How to Wire Your Ceiling Fan

LISTED OUTLET BOX
BLACK FAN WIRE
BLACK
GREEN WIRE
(GROUND)
FROM
HANGER
BRACKET
GROUND
WIRE
GREEN WIRE (GROUND)
FROM HANGER BALL
LISTED WIRE CONNECTOR (4)
Figure 12
Please contact 1-800-654-3545 for further assistance
9
EMERSON FAN CONTROL
LIGHT
RED
CONTROL
WHITE
WHT.
GROUND
GROUND
BLUE
THREE - CONDUCTOR CABLE
WITH GROUND BETWEEN
CEILING AND WALL OUTLET
BOXES
emersonfans.com
U.L. Model No.: CF4801 and CF4501
BLACK
(HOT)
TO 120
VOLT
SUPPLY