Controller Options; Installing A Storage Controller - HP ProLiant DL360e Gen8 User Manual

Hide thumbs Also See for ProLiant DL360e Gen8:
Table of Contents

Advertisement

CAUTION:
all bays are populated with either a component or a blank.
Install the drives
16.

Controller options

The server ships with an embedded Smart Array B120i controller. For more information about the controller
and its features, see the HP Dynamic Smart Array RAID Controller User Guide on the HP website
(http://www.hp.com/go/smartstorage/docs).
Upgrade options exist for an integrated array controller. For a list of supported options, see the product
QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin).
To configure arrays, see the HP Smart Storage Administrator User Guide on the HP website
(http://www.hp.com/go/smartstorage/docs).
The server supports FBWC. FBWC consists of a cache module and a capacitor pack. The DDR cache module
buffers and stores data being written by the controller. When the system is powered on, the capacitor pack
fully charges in approximately 5 minutes. If a system power failure occurs, a fully charged capacitor pack
provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR
memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.
The data protection and the time limit also apply if a power outage occurs. When power is restored to the
system, an initialization process writes the preserved data to the storage drives.
CAUTION:
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.
CAUTION:
the capacitor pack while an array capacity expansion, RAID level migration, or stripe size
migration is in progress.
CAUTION:
before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds,
do not remove the cable from the cache module. The cache module is backing up data. Data will
be lost if the cable is detached when the amber LED is still flashing.
IMPORTANT:
low charge a POST error message appears when the server is powered up, indicating that the
capacitor pack is temporarily disabled. No action is necessary. The internal circuitry
automatically recharges the capacitors and enables the capacitor pack. This process might take
up to 4 hours. During this time, the cache module functions properly but without the performance
advantage of the capacitor pack.

Installing a storage controller

HP recommends installing the storage controller option in a full-height expansion slot for better cable routing.
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP Product Bulletin website (http://www.hp.com/go/productbulletin).
To prevent improper cooling and thermal damage, do not operate the server unless
("Installing a hot-plug
drive" on page 32).
The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
To prevent a server malfunction or damage to the equipment, do not add or remove
After the server is powered down, wait for 30 seconds, and then check the amber LED
The capacitor pack might have a low charge when installed. If the pack does have
Hardware options installation 38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents