System Information; Offset Mode; Pan; Tilt - Chauvet Rogue R2 Spot User Manual

Hide thumbs Also See for Rogue R2 Spot:
Table of Contents

Advertisement

Operation
System
Information

Offset Mode

Pan

Tilt

Gobo

Gobo Rotate

Gobo 2

Color 1

Color 2

Prism

Focus

Iris

Frost

Dimmer

FO. Yellow Edge

-16-
This programming level shows standard information regarding the product's operating status.
·
Starting from the Main Level screen, select Sys Info, press <ENTER>.
·
Ver: The current software version is displayed on the screen.
·
Running Mode: The current Running mode is displayed on the screen.
·
DMX Address: The current DMX address is displayed on the screen.
·
Temperature: The current product temperature is displayed on the screen.
The Offset mode provides fine adjustments for the home position of all the moving parts in the
optical path as well as the pan and tilt movements. This way, when in their home position, the
moving parts do not show any border or reduce the light output.
1. Starting from the Main Level screen, Press and hold <MENU> until the password screen
appears.
2. Using <UP> to increase the number value and <DOWN> to move to the next column,
enter 2323, press <ENTER>. This brings you into the Zero Adjust menu screen.
1. Highlight PAN, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight TILT, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight GOBO, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight GOBO ROT, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight GOBO2, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight COLOR1, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight COLOR2, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight PRISM, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight FOCUS, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight IRIS, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight FROST, press <ENTER>.
2. Select 000–255, press <ENTER>.
1. Highlight DIMMER, press <ENTER>.
2. Select 000–255, press <ENTER>.
Reserved for future use.