Specifications - Generac Power Systems 005818-0 Features & Specifications

Ecogen series residential standby generators air-cooled gas engine
Hide thumbs Also See for 005818-0:

Advertisement

EcoGen™ - 6 kW
Generator
Model
Rated Maximum Continuous Power Capacity (LP)
Rated Voltage
Rated Maximum Continuous Load Current – 120 VAC
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Battery Requirement (not included)
Unit Weight (Pounds/Kilos)
Dimensions (L x W x H) Inches/mm
Sound output in dB(A) at 23 ft. with generator operating at normal load
Engine
Type of Engine
Number of Cylinders
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Governor System
Compression Ratio
Starter
Oil Capacity Including Filter (quarts/liters)
Oil Reservoir Capacity (quarts/liters)
Operating RPM
Fuel Consumption
ft 3 /hr (gal/hr)
Liquid Propane
1/2 Load
Full Load
Required fuel pressure to generator fuel inlet at all load ranges - 11 to 14 inches of water column for LP gas
For Btu content, multipy ft
3
/hr by 2520
Controls
2-Line Plain Text LCD Display
Mode Switch
-Auto
-Off
-Manual/Test (start)
Starter Lock-out
2.5 Amp Smart Battery Charger
Automatic Voltage Regulator w/Overvoltage Protection
Automatic Low Oil Pressure Shutdown
Overspeed Shutdown
High Temperature Shutdown
Overcrank Protection
Safety Fused
Low Battery Protection
50 Event Run Log
Internal Fault Protection
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F). Sound output ratings from certain points on the generator
subject to change based on installation parameters.
005818-0 (6kW)
6,000* Watts
120 VAC (240 VAC capable w/kit)
50 Amps (25 @240 VAC)
50 Amps (25 after conversion)
1
2
60Hz
1
Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum
387/175.5
48 x 25 x 29 [1218 x 638 x 732]
52
GENERAC OHVI
2
530cc
Aluminum w/Cast Iron Sleeve
Overhead Valve
Solid-state w/Magneto
Electronic
9.5:1
12 Vdc
1.7Q/1.6L
4.2Q / 4.0L
2,600
30.8/0.85
48.2/1.32
Simple user interface for ease of operation.
Puts unit in standby mode, waiting for inverter start call.
Stops unit. Power is removed. Control and charger still operate.
Start with starter control, unit stays on.
Starter cannot re-engage until 5 sec. after engine has stopped.
Standard
Standard
Standard
Standard, 72Hz
Standard
Standard
Standard
Standard
Standard
Standard
®

specifications