General Instructions; General Information - Napoleon Torch GT8P Installation And Operation Instructions Manual

Table of Contents

Advertisement

4
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for
example: in Massachusetts State:
• The fi replace damper must be removed or welded in the open position prior to installation of a fi replace insert or gas log.
• A carbon monoxide detector is required in all rooms containing gas fi red appliances.
• The appliance off valve must be a "T" handle gas cock.
• The fl exible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
• WARNING: This product must be installed by a licensed plumber or gas fi tter when installed in the Commonwealth of Massachusetts.
In absence of local codes, install to the current CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas
Code, ANSI Z223.1, and NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with
the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54
in the United States.
The fi replace and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5 kPa). The fi replace must
be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fi replace is installed directly on carpeting, vinyl tile or other
combustible material other than wood fl ooring, the fi replace shall be
installed on a metal or wood panel extending the full width and depth.
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
Altitude
Maximum Input
Maximum Output
Effi ciency
Minimum Inlet Gas Suppy Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* When the fi replace is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft.
This fi replace is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile home
installation.
The natural gas model can only be installed in a mobile home that is permanently positioned on its site and fueled with
natural gas.
This fi replace may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes.
This fi replace is only for use with the type of gas indicated on the rating plate. This fi replace is not convertible for
use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Purge all gas lines with the glass door of the fi replace open. Assure that a continuous gas fl ow is at the burner
before closing the door.
Objects placed in front of the fi replace must be kept a minimum of 48" from the front face of the unit.
Use only Napoleon® accessories designed for and listed with the model.
W415-0619 / B / 03.03.08

GENERAL INSTRUCTIONS

GENERAL INFORMATION

RATES AND EFFICIENCIES
NATURAL GAS
4.5" Water Column
7" Water Column
3.5" Water Column
0 - 4,500*
6,000
4,680
78%
PROPANE GAS
0 - 4,500*
6,000
4,680
78%
11" Water Column
13" Water Column
10" Water Column

Advertisement

Table of Contents
loading

This manual is also suitable for:

Torch gt8n

Table of Contents