Proceed once the vent installation is complete.
Note: All gas connections must be contained within the fi replace when
complete.
1. The fi replace is designed to accept a 1/2" gas supply line. The fi replace is
equipped with a 1/2" manual shut-off valve.
2. The access to the gas inlet is located on the bottom of the outer shell.
3. The shut off must always be within the outer shell.
4. When fl exing any gas line, support the gas valve so that the lines are not
kinked.
5. Check for gas leaks by brushing on a soap and water solution.
Do not use open fl ame.
WARNING
!
RISK OF ELECTRIC SHOCK!
Control and valve operate with 110v.
HARD WIRING CONNECTION
IT IS NECESSARY TO HARD WIRE THIS
FIREPLACE.
Permanently framing the fi replace with an enclosure,
requires the fireplace junction box to be hard
wired.
This fi replace must be electrically connected and
grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1
CANADIAN ELECTRICAL CODE in Canada or
the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL
CODE in the United States.
1

GAS INSTALLATION

ELECTRICAL CONNECTION

IGNITOR
WIRE
CONTROL MODULE
FIGURE 18
110v
POWER
SUPPLY

STAND-OFF ASSEMBLY

FIGURE 19a&b
FIGURE 17
Do NOT use the fireplace if any part has been
under water. Call a qualified service technician
IMMEDIATELY to have the fi replace inspected for
damage to the electrical circuit.
IGNITOR
BROWN
W
H
I
T
E
GROUND
GROUND
JUNCTION BOX
(c/w 2 receptacles)
2
13
FIGURE 16
GAS
VALVE
1 2
3 4
B
L
SWITCH
A
C
K
W415-0619 / B / 03.03.08