OPERATING INSTRUCTIONS

When lit for the fi rst time, the fi replace will emit a slight odour for
a few hours. This is a normal temporary condition caused by the
curing of paints and lubricants used in the manufacturing process
and will not occur again. Simply open a window to suffi ciently
ventilate the room.
After extended periods of non-operation such as following a
vacation or a warm weather season, the fi replace may emit a
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. This fi replace is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
B. Before operating, smell all around the fi replace area for
gas and next to the fl oor because some gas is heavier than
air and will settle on the fl oor.
C. Do not use this fi replace if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
fi replace and replace any part of the control system and any
gas control which has been under water.
1. STOP! Read the safety information located above.
2. Turn off all electric power to the fi replace.
3. This fi replace is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
4. Remove the glass door.
5. Wait fi ve (5) minutes to clear out any gas. If you smell gas
including near the fl oor STOP! Follow "B" in the above safety
information on this label. If you don't smell gas go to the next
step.
6. Replace the glass door.
7. Turn on all electric power to the fi replace.
1. Turn the fi replace switch to the OFF position.
2. Turn off all electrical power to the fi replace if service is to
be preformed.
RATING LABEL LOCATION: The rating label is located under the control panel and is chained to the fi replace.
CERTIFIED UNDER : CSA 2.22-2007, ANSI 21.50-2007 VENTED GAS FIREPLACE
R
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED SITTING ROOM INSTALLATION.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA
Z240MH SERIES GAS EQUIPPED MOBILE HOMES. IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD. TITLE 24 DFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
CM
C
US
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES,
ANSI/NFPA 501A.
REFERENCE #15901
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
WARNING:
DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT WITH
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP
6"
RECESSED DEPTH
FLOOR
0"
VENT
SIDES
0"
BACK
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS
ARE 10 INCHES AND 10 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS
ARE 36 INCHES AND 10 FEET RESPECTIVELY.
W415-0619 / B / 03.03.08
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
RATING PLATE
DO NOT REMOVE.
MODEL
CERTIFIED FOR CANADA AND USA
GT8N
(NATURAL GAS)
0-4500FT (0-1370m)
6,000 BTU/h
#56
MANIFOLD PRESSURE: 3.5" WATER COLUMN
VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOOR. CERTIFIED WITH THIS UNIT ONLY.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT
KITS, SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
7"
VENT-AIR INTAKE SYSTEM.
1"
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE
1 1/2"
RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY
LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME WHERE NOT
PROHIBITED BY LOCAL CODES. SEE OWNER'S MANUAL FOR DETAILS. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A
CERTIFIED KIT IS USED.
slight odour for a few hours. This is caused by dust particles in
the heat exchanger burning off. Open a window to suffi ciently
ventilate the room.
Purge all gas lines with the glass door of the fi replace open.
Assure that a continuous gas fl ow is at the burner before
closing the door.
WHAT TO DO IF YOU SMELL GAS:
Turn off all gas to the fi replace.
Open windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fi re
department.
8. Turn the fi replace switch to the ON position.
9. If fi replace will not operate, follow instructions "To Turn Off
Gas" and call your service technician or gas supplier.
FIGURE 32
3. Turn manual shut-off valve clockwise to
Do not force.
MODEL
(PROPANE)
ALTITUDE
0-4500FT (0-1370m)
INPUT
6,000 BTU/h
ORIFICE
#69
MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
GT8
SERIAL NUMBER:
GT8P
W385-0381 / A
off.