Chlorine (Sodium Dichlor) - HotSpring Vista Owner's Manual

Portable spas
Hide thumbs Also See for Vista:
Table of Contents

Advertisement

F. When the Free Available Chlorine is within the recommended range, the spa is ready to be enjoyed.
WARNING: There are several forms of stabilized chlorine available for use in spas and swimming pools and each form has specific
chemical characteristics. It is extremely important that the one you choose is specifically designed for use in spas. Use of an incorrect product
such as tri-chlor, which has a very low pH (2.6), dissolves too quickly in hot water resulting in extremely high levels of chlorine, and is designed
for concrete or plaster swimming pools, WILL cause damage to your spa. Use of a liquid or any type of compressed bromine or chlorine, acid
or any type of sanitizer which is not recommended by Watkins Manufacturing Corporation WILL damage your spa and is specifically not
covered under the terms of the limited warranty.
IMPORTANT: Granulated chlorine (sodium dichlor) will degrade if stored improperly. We recommend purchasing chlorine in one , two, or five
pound containers and storing it in a cool, dry place to maintain its potency.
SUPER CHLORINATION
Super Chlorination is designed to "burn-off" the build-up of chloramines (used chlorine), to eliminate the chlorine smell and to allow the proper
level of free chlorine to be maintained.
When giving your water a super chlorination treatment, open the cover at least half way to allow the chlorine gas to vent off. The high
concentration of chlorine gas which may exist as a result of super chlorination (not daily sanitation) may eventually cause discoloration or
degradation to the bottom of the cover or the tile grouting, which would not be covered under the terms of your warranty.
IMPORTANT: Always allow the Free Available Chlorine to fall below 5 ppm before using your spa.
WARNING: Never leave an open spa unattended, especially if there are children present!
BUILDING A SANITIZER ROUTINE
During the first month of ownership, measure the sanitizer residual daily in order to establish standards for User Load and Usage Time versus
Sanitizer Needed.
• The User Load of the spa is the number of times anyone enters the spa.
• The Usage Time is simply the amount of time a user spends in the spa.
• Sanitizer Needed is the amount of Free Available Chlorine needed to accommodate the number of users and their combined usage time.
For example, two spa users who regularly use the spa once an evening for twenty minutes create a specific and somewhat consistent demand on
the sanitizer. During the first month of ownership, these two users can determine exactly how much sanitizer to use in order to maintain the proper
residual. If, at any time, the user load and/or usage pattern changes dramatically (invited guests), the amount and frequency of sanitizer required
increases dramatically.
The greater the usage time, or the bather load, the faster the residual value is diminished.
SUPPLEMENTAL WATER MAINTENANCE
Proper water sanitation and mineral balance (pH control) are absolutely essential for a complete spa water maintenance program. Here are three
other popular water additives that are optional:
Mineral Deposit Inhibitors
As water evaporates from your spa and new water is added, the amount of dissolved minerals will increase. (Minimize evaporation by keeping the
cover on the spa whenever possible.) The spa water may eventually become "hard" (Calcium Hardness too high) enough to damage the heater by
calcifying its surface. Proper pH control can minimize this.
Normal soap build-up will require water replacement regularly enough that mineral deposits normally are not a problem.
Occasionally, high iron or copper content in the water may produce green or brown stains on the spa. A stain and scale inhibitor may help to
reduce these metals.
NOTE: Well water may contain high concentrations of minerals. The use of a low water volume, extra-fine pore water filter (in-line pre-filter such as
®
the FreshStart
pre-filter) will help to remove many of the larger particles during the filling of the spa. In-line pre-filters can be purchased at
10,000
®
your local Hot Spring
dealer.
Foam Inhibitors
Spa water requires changing due to the buildup of soap in the water. Typically, soap will cause the spa water to foam when the jets are used.
Soap is introduced into the spa water from two sources: users' bodies, which retain a soap residual after showering, and swimming apparel,
which retains soap after washing.
Foam inhibitors can suppress foam, but cannot remove soap from the water. Soap is very difficult to remove from the water because soap is not
oxidized by any chemical added to the spa. Only ozone can oxidize soap.
Eventually the soap build-up in the water will be concentrated, resulting in an unclean feeling on the bather's skin, which is impossible to remedy.
When this occurs, it's time to drain and refill the spa. Depending on the soap input, the water should last about four months before needing to be
drained.
Water Quality and Maintenance
Page 57

Hide quick links:

Advertisement

Table of Contents
loading