Heatiator CL36D Owner's Manual

Wood burning fireplace
Hide thumbs Also See for CL36D:
Table of Contents

Advertisement

Quick Links

Models:
CL36D
CR36D
Wood Burning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL36D and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatiator CL36D

  • Page 1 • For use with solid wood fuel or decorative technicians supervised by an gas appliance only. NFI certifi ed professional. • DO NOT install unvented gas logs. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 2: Congratulations

    ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Note: An arrow ( ) found in the text signifi es change in content. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 3: Table Of Contents

    Tools and Supplies Needed E. Contact Information G. Fireplace System Requirements H. Inspect Fireplace and Components Framing & Clearances A. Select Fireplace Location B. Clearances C. Sidewalls/Surrounds D. Frame the Fireplace Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 4: Limited Warranty

    Limited Warranty Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 5 Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 6: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 7: User Guide

    (not shown) Section 2.H. Outside Air Control Handle Wood Fuel Section 2.I. Section 2.M. IN - closed OUT - open Hearth Clear Space Section 2.L. Figure 2.1 General Operating Parts Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 8: Seasoned Wood

    fi rewood, placed to allow combustion air and fl ames between them. CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 9: Glass Doors

    HOT when fi replace is in operation. Adjust BEFORE lighting fi re. 18 in. (45.7 cm) Clear Space from Opening of Fireplace 48 in. (121.9 cm) Clear Space Front of Fireplace Figure 2.3 Clear Space Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 10: Wood Fuel

    fi relogs that have been evaluated for the application in manufactured fi replaces and refer to fi relog warnings and caution markings on packaging prior to use. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 11: Maintenance And Service

    Top Cover Chimney Slip Chase Section ST375 TS345/TS345P TCT375 TR344/TR342 Square Square Terra Cotta Round Termination Cap Termination Cap Termination Caps Termination Cap Figure 3.1 Chimney & Termination Cap Cleaning Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 12: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fi replace glass cleaner (consult with your dealer) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 13: Troubleshooting Guide

    Add glass doors to slow down air fl ow. Overdrafting Check for correct vent height; too much vertical height creates overdrafting. Check location of vent termination (refer to chimney assembly section). Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 14: Getting Started

    (1.83m) off (Section 11) ground level. Hearth extension Outside (Section 11) combustion air Factory-built fireplace (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 15: Design And Installation Considerations

    Tight sealing construction of the structure • Mechanical exhausting devices NOTICE: Hearth & Home Technologies Inc. recommends • Improper location of the chimney the use of direct vent fi replaces in basements. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 16: Locating Fireplace & Chimney

    Recommended: • Below adjacent structure • Insulated exterior chase • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Figure 5.2 Recommended Chimney Locations Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 17: Tools And Supplies Needed

    Hearth Refractory • Grate Assembly • Hearth Extension (required, sold separately) • Chimney Air Kit (required in Canada) • Chimney System (required, sold separately) • Termination Cap (required, sold separately) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 18: Framing & Clearances

    • Clearances (Section 45 in. 6.B.) • Mantel Projections (Section 11.E.) 23 in. • Fireplace Dimensions (Section 13.A.) 48 in. Min. Figure 6.1 Fireplace Locations (Framing dimensions shown) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 19: Clearances

    1/2 in. (13 mm) to back & side of appliance 0 in. to floor Figure 6.2 Clearances to Combustible Materials Note: Chimney air kit is not shown, but is required in Canada. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 20: Sidewalls/Surrounds

    16 3/4 in. Minimum 18 in. Min. 14-1/2 in. 20 in. 39 deg 50 deg 16 3/4 in. Minimum 18 in. Min. Figure 6.3 Mantel Leg or Wall Projections Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 21: Frame The Fireplace

    Drywall fireplace opening. 42-1/2 in. (1080 mm) 1/2 in. (13 mm) Clearance 22 1/2 in. (572 mm) * 1/2 in. (13 mm) Clearance Figure 6.4 Framing the Fireplace Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 22: Installation Of Fireplace

    fl ange. • Check fi replace opening for square to ensure proper fi t of glass doors. Measure diagonals of fi replace opening to make sure they are equal. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 23 Figure 7.4 Outside Combustion Air Placement Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 24: Install Outside Air Kit

    Blockages could cause combustion air starvation. Flexible Duct (not supplied) Outside Air Plate Outside Air Assembly Hood 2 Wire Ties Figure 7.5 Outside Air Installation Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 25: Chimney Assembly

    Lock chimney sections together firmly to resist movement Ceiling firestops are required where chimney passes through ceiling or floor Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 26: Chimney Requirements

    SL312 10-3/4 Effective Height 50 ft (15.24 m) max. height SL318 16-3/4 SL324 22-3/4 SL336 34-3/4 SL348 46-3/4 1187 * Dimensions refl ect effective height. Figure 8.2 Chimney Requirements Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 27: Using Offsets/Returns

    49-1/4 1251 94-1/2 2400 Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 28: Assemble Chimney Sections

    Catalog # Angle FS338 14-1/2 14-1/2 0° Figure 8.4 Assembling Chimney Sections FS339 14-1/2 18-3/8 15° FS340 14-1/2 30° Figure 8.5 Installing the Ceiling Firestop Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 29: Install Attic Insulation Shield

    14-1/2 in. (368 mm) diameter 6 Tabs bent in 90° Insulation Insulation 10-1/2 in. Ceiling Firestop Pipe (267 mm) Figure 8.8 Install Attic Insulation Shield (fi restop below ceiling) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 30: Cut Out Hole In Roof

    Caulk the fl ashing plate and roof junction as well as the vertical seam on the fl ashing. All nail heads must be caulked with a roofi ng sealant. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 31: Chimney Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 8.10 Multiple Chimney Locations Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 32: Chase Installations

    Failure to prevent contact between insulation or other Insulation Insulation materials and chimney system may cause overheating False Ceiling False Ceiling and fi re. Chimney Figure 9.1 Chase Assembly Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 33: Install Fireplace & Chimney

    Chase Top Construction Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). Figure 9.4 Installing a TR344 Round Termination Cap Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 34 1-1/2 in. (38 mm) Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.8 Installing a TCT375 Terra Cotta Cap Figure 9.6 Installing an ST375 Square Termination Cap Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 35: Shrouds

    22 x 22 20 x 20 Min. Opening Min. 432 x 432 559 x 559 508 x 508 Width Base Dim. Min. Base Dim. Figure 10.2 Open Top Shroud Dimensions Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 36 Min. Height Above Radiation Shield Termination Height 3 in. (76 mm) Radiation Minimum Shield Height Base Dimension Min. Opening Width Min. Opening Width Min. Opening Height Figure 10.4 Roofed Style Shroud Dimensions Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 37: Finishing

    5-1/8 in. Common Brick 0.20 5-1/8 in. Ceramic Tile 12.50 0.08 12-1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14-5/8 in. - 20-3/8 in. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 38: Finishing Material

    2 in. (51 mm) Figure 11.3 Decorative Facing Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 39: Combustible Mantel

    Measured from top of fireplace opening slate, glass, plasters Seal joint with non-combustible sealant Figure 11.4 Clearances to Mantels or other Combustibles above Fireplace Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 40: Sidewalls/Surrounds

    18 in. Min. 14-1/2 in. 20 in. 39 deg 50 deg 16 3/4 in. 18 in. Min. Minimum Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 41: Accessories

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 12.1 Gas Line Installation Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 42: Reference Materials

    Tube Assembly Assembly 2 Wire Ties AK14 Bi-fold Glass Doors Outside Air Kit with End Panel DM1436 Series See your Heatilator dealer for a complete listing of optional components. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 43: Chimney Components

    (133 mm) 4 in. (102 mm) Outside 4-3/4 in. (121 mm) 10-1/2 in. Diameter (287 mm) Effective Height 10-1/2 in. (267 mm) CAK4A Chimney Air Kit SL3 Vent Stabilizer Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 44 24-5/8 in. 31 in. (625 mm) (787 mm) 10-1/2 in. (267 mm) RF371 Roof Flashing CB876 Chimney Joint Band 7 3/4 in. 26 in. TR-TVK TR Top Vent Kit CT-3A Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 45 16 1/4 in. (413 mm) 26 1/2 in. (673 mm) 28 5/8 in. (727 mm) LDS-BV Decorative Shroud Catalog # 18 in. 12.5 15.5 (457 mm) LDS-BV TS345/TS345P Square Termination Cap Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 46: Service Parts

    D. Service Parts Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 47 D. Service Parts (continued) Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...
  • Page 48: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heatilator • CL36D, CR36D • 12538 • Rev V • 05/09...

This manual is also suitable for:

Cr36d

Table of Contents