B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fi re.
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
Combustible Mantels
1/2 in.
Thick Wall
Sheathing
14 in.
MIN.
Figure 13.5 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 IN.
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Figure 13.6 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
52
12 in.
MAX.
MEASUREMENT FROM TOP OF
FIREPLACE OPENING
12 IN.
MAX.
14 IN.
MIN.
1 IN.MIN.
4 IN.
MAX.
Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
2 IN.
MINIMUM
FIREPLACE
OPENING
6 IN.
MINIMUM
Figure 13.7 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Non-combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
3 IN.
FIREPLACE
MINIMUM
OPENING
7 IN.
Figure 13.8 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)