Top Vent - Vertical Termination
No Elbows
V
= 44 ft. Max. (13.4 m)
1
Note: If installing a vertical vent/termination off the top of the
appliance, the optional exhaust restrictor may be needed.
Note: Use SLP Series
components only.
Figure 7.7 Vertical Vent Maximum
Exhaust restrictors are recommended for these vertically
terminated products which have excessive draft. Exhaust
restrictors will compensate for high draft, and restore vi-
sual fl ame height. If the vent confi guration has a total ver-
tical of 15-44 feet, an exhaust restrictor may be needed.
The exhaust restrictor can be located in the appliance
manual bag.
28
V
1
Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12
Exhaust restrictor Instructions
1. Locate the two pilot holes located in the inside fi rebox
heat shield as shown in Figure 7.8.
2. Center the exhaust restrictor such that the through
holes in the vent restrictor align with the pilot holes in
the restrictor.
3. Use two 1/2 in. self-piercing screws to secure vent
restrictor to fi rebox heat shield. See Figure 7.9.
PILOT HOLES
Figure 7.8 Location of Pilot Holes
Figure 7.9 Exhaust Restrictor Installation
4. In some applications, such as those where the fi re-
place is elevated off the fl oor, the vent restrictor may
be painted, but painting is not required.
NOTICE: Before painting, contact your dealer for
information on the appropriate high temperature paint.