Installation Instructions
Audio Alarm Verification Connections (AAV, "listen-In")
Refer to the connection diagrams below. One diagram shows connections when a 4285/4286 Phone
Module is used, the other shows connections when the 4285/4286 is not used.
Connections use one of the on-board triggers.
U L
UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO UVS
system)
Suggested AAV Module: ADEMCO UVS (shown) or Eagle 1250
NOTES
• Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode:
select zone type 60 and output action 1 (close for 2 seconds) or action 2 (stay closed).
• For voice session monitoring, connect a zone to UVCM module terminals 6 & 7, and program the
zone as zone type 81 (*56 Menu mode).
E.g.,
Using output 18 for the trigger, program an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = OFF
2 = ON
3 = OFF
3 = OFF
4 = ON
4 = OFF
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 14. Connection of AAV Unit When Not Using a 4285/4286 Phone Module
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = OFF
2 = ON
3 = OFF
3 = OFF
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 15. Connection of AAV Unit When Using a 4285 or 4286 Phone Module
2-12
CONTROL
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
MODULE
FALLING VOICE TRIG
GND
+12VDC IN
CONTROL
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
RING
MODULE
TIP
FALLING VOICE TRIG
GND
+12VDC IN
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
4
5
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
4
5
EOL
RING
TIP
OPTIONAL
MONITORING
ZONE
CONNECTION
(USE ZONE
TYPE 81)
4285/4286
4
3
2
1
EARTH
GROUND
21
22
23
24 25
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE
EARTH
GROUND
21
22
23
24 25
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE