Lamp Replacement; To Change The Lamp - Martin RoboColor III User Manual

Color changing system
Table of Contents

Advertisement

L A M P R E P L A C E M E N T
Warning!
Disconnect the fixture from AC power before removing any cover.
To reduce the risk of the lamp shattering, never exceed the average lamp life,
listed below, by more than 25%. Disconnect the system from AC power if the
lamp blows. Allow the heads to cool for 15 minutes before installing a new lamp.
The RoboColor III comes with the Martin 150 W Metal Halide lamp installed.
The Osram HTI 150 and GE CSS 150 may be used as well. Installing any other
lamp may damage the fixture.
P/N
Average Life
Color Temp.
Output

To change the lamp

1
Remove the 3 thumbscrews that
secure the access plate of the lamp
socket assembly at the rear of the
head and withdraw the lamp socket
assembly.
2
Remove the old lamp from the
socket.
3
Holding the new lamp in a clean cloth
(do not touch the glass), carefully
insert it firmly and squarely into the
lamp socket.
4
If your fingers touch the glass, clean the bulb with a clean, lint-free cloth
wetted with alcohol.
5
Replace the lamp-socket assembly and tighten the thumbscrews.
Do not touch the
glass
User Manual
Martin 150 W
Metal Halide
97010107
2000 h
5000K
900 lm
Service and Maintenance
Osram HTI 150
97010108
750 h
6500K
1200 lm
Remove
screws.
Withdraw lamp socket assembly.
Hold only by the
ceramic base.
GE CSS 150
97010104
1000 h
5000K
900 lm
13

Advertisement

Table of Contents
loading

Table of Contents