On the ballast, move the BLACK wire to the correct voltage terminal. Use the
following table to select the correct voltage setting.
3
Re-assemble the unit.
Ballast
230V/50Hz
240V/50Hz
250V/50Hz
50 Hz Model
Mains supply
210V - 235V
235V - 245V
245V - 255V
F U S E S
Should the RoboColor III system cease to work it may be due to a blown fuse.
This section describes how to replace the fuses.

To replace the pri mary fuse

The primary fuse is located inside the IEC mains input socket at the rear of
the controller. Use a small screwdriver to pry open the fuse holder and
replace the fuse with one of the same size and rating. The fuse rating is also
printed on the serial number label.
16
50 Hz Version
Ballast tapping
230V
240V
250V
Mains fuse
6.3AT/250V (slow
IEC mains input
socket.
Service and Maintenance
Ballast
210V/60Hz
220V/60Hz
230V/60Hz
60 Hz Model
Mains supply
200V - 215V
215V - 225V
225V - 235V
60 Hz Version
Ballast tapping
210V
220V
230V