(46) SET MAX ADDRESS EXT (X'37'): Option (customizing)

Description
This command limits specifications so that the highest address that can be
accessed by users can be specified only in LBA mode.
The address information specified with this command is set in words 1, 54, 57, 58,
60, 61, and 100 to 103 of the IDENTIFY DEVICE command response. If read or
write processing is executed for an address that is outside of the new address
space, an ID Not Found error occurs.
If the SC register bit is 0 and the value volatile (VV) bit is 1 when this command
is executed, the specified values are maintained after a power-on reset. If the VV
bit is 0 when the command is executed, the specified values are invalidated during
the power-on sequence. If the VV bit is 1, the highest address value is defined as
the last value specified. (If the VV bit is not set to 1, the highest address is the
default value.)
After a power-on reset is performed, a host can issue the SET MAX ADDRESS
(EXT) command only once if the VV bit is 1. If the SET MAX ADDRESS (EXT)
command is issued twice or more, an ID Not Found error occurs.
When the SET MAX ADDRESS EXT command is executed, all SET MAX
ADDRESS commands are aborted. The address value returns to the origin when
the SET MAX ADDRESS EXT command is executed using the address value
returned by the READ NATIVE MAX ADDRESS command.
Error reporting conditions
This command is issued twice or more in an operation sequence. (ST = 51h,
ER = 10h, ID Not Found)
The READ NATIVE MAX ADDRESS EXT command (27h) is not issued
immediately before this command (ST = 51h, ER = 04h, Aborted) is issued.
This command is issued while LBA = 0 (ST = 51h, ER = 04h, Aborted)
The SET MAX ADDRESS command has already been issued.
C141-E202-01EN
5.3 Host Commands
5-117