FieldServer FS-8700-66 GE SNP Manual page 28

Ge-snp serial driver
Hide thumbs Also See for FS-8700-66 GE SNP:
Table of Contents

Advertisement

Page 28 of 29FS-8700-66_GE-SNP Manual
Decimal
Hex
Description
-62
0C2
The OEM key is NULL (inactive).
-63
0C1
Invalid block state transition.
-64
0C0
Bad OMF record checksum in store.
-65
0BF
Illegal OMF record type/data contents.
-66
0B
Bad Block Type given in Load/Store.
-67
0BD
Block Set (subblock name) not found.
-68
0BC
Block Type (e.g., data) not found.
-69
0B
Maximum length of a partial store exceeded.
-70
0B
Block Set already exists, cannot create.
-71
0B9
Executable flag in TYPDEF record not set.
-72
0B8
Size of the Segment Selector Table in TYPDEF record is not correct.
-73
0B7
Segment length in Verify not equal to the segment length of block in the PLC.
-74
0B6
Cyclic Redundancy Check (CRC) checksum comparison in Verify failed.
-75
0B5
Additive checksum comparison in Verify failed.
-76
0B4
Attempt to alter interrupt list in MAIN DECL BLOCK during RUN MODE.
-77
0B3
Length limit exceeded; includes read past end of transferred data, writes past
ofprogram block.
-78
0B2
Program block already exists and cannot be replaced.
Minor Error Status Codes: Program Load and Store Requests
Decimal,
Hex,
80
50
81
51
85
55
86
56
87
57
88
58
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com
Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com
Description
Problem with sending mail to the slave Service Request task. (Series 90-70 PLC
CPUs only).
Problem with getting mail from the slave Service Request task. (Series 90-70
PLC CPUs only).
Slave SNP task timed out before receiving SRP response. (Series 90-70 PLC
CPUs only).
Slave SNP task could not find the requested Datagram connection. (Series 90-70
PLC CPUs only).
Slave SNP task encountered an error in trying to write the Datagram. (Series 90-
70 PLC CPUs only).
Slave SNP task encountered an error in trying to update the Datagram. Series
90-70 PLC CPUs only).
Page 28 of 29

Advertisement

Table of Contents
loading

Table of Contents