Power Linking
DMX Linking
DMX Personalities
Master/Slave
Connectivity
COLORado™ 2-Quad Zoom Tour User Manual Rev. 1
The COLORado™ 2-Quad Zoom Tour supports power linking. You can power link up to
5 products at 120 V; up to 10 at 208 V; or up to 10 at 230 V.
This product comes with a power input cord. Power linking cables are available from
CHAUVET® for purchase.
You can link the COLORado™ 2-Quad Zoom Tour to a DMX controller using a 3- or 5-pin
DMX connection. If using other DMX-compatible products with the COLORado™ 2-Quad
Zoom Tour, you can control each individually with a single DMX controller.
The COLORado™ 2-Quad Zoom Tour uses the standard DMX data connection for the
TOUR, TR16, STD.Y, ARC.1, AR1.D, ARC.2, AR2.D, AR2.S, AR2.Z, and HSV DMX
modes.
·
Refer to the
Introduction
·
Refer to the
Operation
Zoom Tour to work in these personalities.
·
The
DMX Values
section provides you with detailed information regarding the DMX
personalities.
The Master/Slave mode allows a COLORado™ 2-Quad Zoom Tour (the master) to
control one or more COLORado™ 2-Quad Zoom Tours (the slaves) without a DMX
controller. One COLORado™ 2-Quad Zoom Tour becomes the master when running an
Auto or Custom program, or by being in a Static mode.
You must configure each slave's control panel to operate in Slave mode. During
Master/Slave operation, the slaves will operate in unison with the master.
DO NOT connect a DMX controller to products operating in Master/Slave mode.
The DMX controller signals may interfere with the signals from the master.
The
Operation
section of this manual provides detailed instructions on how to configure
the master and slaves.
If you are not familiar with or need more information about DMX standards, Master/Slave
connectivity, or the DMX cables needed to link this product to a DMX controller,
download
the
DMX
www.chauvetlighting.com/download/pro.
chapter for a brief description of each DMX personality.
chapter to learn how to configure the COLORado™ 2-Quad
Primer
from
the
CHAUVET®
Setup
website:
-7-